Welcome to B2BAGE
CE/FDA all-in-one EECP Medical machine for heart failure
CE/FDA all-in-one EECP Medical machine for heart failure

Minimum Order: 0
Quality/Safety Certification: 0.00


1 CE ,FDA certified eecp
2.High quality & competitive price
3.Stable,low noise
4adjustable backrest
5 non-surgical eecp

 

EECP TI MACHINES:

 PSK-HEALTH ECP -TI with SpO2

  1. It adopts integration of machinery (All-in-one) design which makes the operation more reasonable and the installation more convenient.

  2. It is more comfortable as the bed is designed based on the principle of human engineering. It makes the treatment more easily.

  3. It adopts modern industrial design which makes the appearance of product luxury and gracious.

  4. The air compressor adopted in the machine is Becker sliding vane rotary vacuum pump which is made in Germany and is full of gas, low noise and light.

  5. It adopts the German Siemens inverter which is good at speed regulating, automatically traced on the basis of the patients ECG data, controls the gas production of the air compressor in real-time so as to conserve energy and protect environmental in maximum.

  6. The angle of the backrest can be adjusted on the basis of patient’s physiological situation.

  7. All the indexes of product have passed the strict test of EU, and have got the CE Certificate.

  8. It adopts the electromagnetic valve with independent intellectual property rights, and the characteristics of inflation and deflation are more excellent.

9. The machine adopts humanistic design which makes operation more convenient, and it has passed the test of bio-compatibility. 

  10It adopts patient protection system, it will automatically protect the patients when an early extra systole, power outage occurs and heart rate goes out of range, etc. 

  11. It adopts special noise reduction and heat dissipation system, and the indexes of the whole machine are much better than National Standard and even to be on a par with American machine.

 

Technical Parameter

 

ECG  Amplifier

Input impedance: >2MΩ

Common-mode rejection ratio: >80dB

Bandwidth: 1-20 Hz on display

 

SpO2 Oxygen Saturation

Oxygen saturation range: 0 to 100%

Accuracy SpO2 (±1 Saturation Deviation)

60-100% ± 3 digits for adults

Using the Finger Clip Sensor

60-100% ± 4 digits using Ear Clip Sensor

 

Triggering Method

External trigger: R-wave of patient ECG

External trigger ratio: 1:1 or 1:2

ECG triggers range: 35-125 ± 1 bpm

 

Filter Technique

Low-pass digital filter eliminates 50/60Hz and high-frequency interference

Treatment Pressure Range 

Adjust from 100-300 mm Hg by PC as needed

 

Cuffs

Calves, lower thighs, and upper thigh/buttocks

(You can choose upper limb cuffs too)

 

Treatment Session Timer

Set treatment time from 15 to 60 minutes maximum. System automatically stops when set time expires.

 

System Protection

Three circuit breakers -Mains and Compressor, and an emergency stop.

 

 

Electrical Performance & System Dimension

Power Requirements:

220V±22V AC, 50/60Hz, 1350W

Dimension: 2150mm×760mm×600mm

Net Weight   178 kg

Operating Environment

Temperature 14 to 104 (-10°C to 40°C )

Relative Humidity <80% (no condensation)

Atmospheric Pressure 700 to 1060 hPa

Atmospheric Free of corrosives gas

 

Transport and Storage Environment

Temperature 14 to 140 (-10 °Cto 60°C)

Relative Humidity 30 to 85% (no condensation)

Atmospheric Pressure 500 to 1060 hPa

Atmospheric Free of corrosive gas

 