Welcome to B2BAGE
GENSET CONTROLLER (AMF)
GENSET CONTROLLER (AMF)

Minimum Order: 0
Quality/Safety Certification: 0.00


1.GU320A GENSET CONTROLLER electronic intelligence power controller.
2. The attractive price and good quanity

 

 

GU320A GENSET CONTROLLER

 

GU320A GENSET CONTROLLER electronic intelligence power controller has inlaid high performance computer chips and various functions, such as measurement, control, protection and remote control all in one, and the controlling program and protective parameters can be changed, completely satisfying requirements of users and professional assembly factories on automatic control of different generator sets.

 

The intelligent controller of generator with a high performance computer chip can modify the control program and protection parameters for the generator. It integrates multiple functions such as measuring, controlling, protection and three remote controlling, etc., which can fully meet the auto control needs of various generator sets for generator users or professional assembling factories.

 

The controller measures and displays all the electrical parameters of generator output as well as the engine speed, oil pressure, water temperature, DC power voltage and operating time, etc. Among them, voltage and current uses virtual value for measurement to assure more accurate data.

 

Chinese-English menu and large screen LCD display.

 

The keys on the controller panel can be used to select control modes, start up operating program, display data and modify protection parameters. The LED indicators can be used to indicate the control modes of controller and the operating state of generator sets. The LCD displays various measuring parameters and states.

 

RS485 or RS232 communication port can be selected to realize remote control. Or communicate it with PC to fully realize the functions of remote communication, measurement and control. The operating parameters of controller can be read and set up.

 

The controller consists of aluminum alloy plate and powder coated steel housing, which are tightly assembled together. All the connections of controller are connected with needle-type terminals with locks, which make the connection, movement, maintenance and replacement easy and convenient.

 

Measure and Display Data:

 

Three-phase Phase Voltage L1-N,L2-N,L3-N

 

Three-phase Line Voltage L1-L2,L2-L3,L3-L1

 

Three-phase Current L1 L2 L3

 

Frequency HZ

 

Three-phase Apparent Power AL1   AL2   AL3

 

Three-phase Power and Total Power L1   P L2   P L3  ?P

 

Three-phase Reactive Power and Total Reactive Power QL1  QL2  QL3  ?Q

 

Sanfeng Power Factor PF L1  PL L2  PF L3

 

Active Power (KWh) ?E

 

Reactive Power (KVArh) ?E

 

Operating Speed of Generator Set RPM

 

Oil Pressure of Engine

 

Water Temperature of Engine

 

Speed Sensor

 

Battery Voltage

 

Operating Time of Generator Set

 

One Line Secondary Analog Input

 

Keys on Panel

 

AUTO Key(Auto Operating Mode)

 

MAN Key (Manual Operating Mode)

 

TEST Key(Test Operating Mode)

 

START Key(Start Up Key)

 

STOP/RESET Key(Stop/Reset Key)

 

L.TEST/MUTE Key (Lamp Test/Mute Key)

 

> Key(Parameter Set Up)

 

v Key(Page Down/Number Descend)

 

^ Key(Page Up/Number Ascend)

 

LED Indicators on Panel:

 

CHARGE FAIL (charge fail)

 

FAIL TO START (fail to start)

 

LOW OIL PRESSURE (low oil pressure)

 

HIGH TEMPERATURE (high water temperature)

 

OVERSPEED (over speed trouble)

 

EMERGENCY STOP (emergency stop)

 

Auto Mode Indicator

 

Manual Mode Indicator

 

Test Mode Indicator

 

Set On Indicator

 

Stop/Fail to Stop Indicator

 

Mute Indicator

 

Switch Quantity Input:

 

Remote switch on signal for generator set

 

Emergency stop signal

 

High temperature signal

 

Low oil pressure signal

 

Back-up state signal

 

Settable Operating Parameters

 

Current Mutual Inductor Ratio(1~5000)

 

Voltage Mutual Inductor Ratio(1~100)

 

Communication Address(1~255)

 

Language(Chinese/English)

 

Low Voltage Alarm Value(AC45~20000V)0(not set )

 

Low Voltage Trouble Value(AC45~20000V)0(not set)

 

High Voltage Alarm(AC45~20000V)29999(not set)

 

High Voltage Trouble Value(AC45~20000V)29999(not set)

 

Over Current Alarm Value(0~9999A)9999(not set)

 

Over Current Trouble Value(0~9999A)9999(not set)

 

Electric Trouble Delay(0~600 sec.)

 

Engine Operating Speed(99-9999RPM)

 

Sensor Frequency Input Value(1-9999Hz)

 

Oil Supply Valve Type(0 Constant Close Type/1 Constant Open Type)

 

Water Temperature Sensor Type(1~8)0(not in use)

 

Oil Pressure Sensor Type(1~9)0(not in use)

 

Speed Sensor Type(0 w/o/1 w/)

 

Start Delay(1~300 sec.)

 

Number of Start(1~10 times)

 

Jigger Time(1~30 sec.)

 

Jigger Interval Time (1~300 sec.)

 

Jigger Cut Off Speed(1~9999RPM)

 

Idle Delay(0~9999 sec.)

 

Safety Supervision Delay Time(0~600 sec.)

 

Cooling Delay(0~600 sec.)

 

Fail to stop Delay(0~60 sec.)

 

Low Speed Trouble Value(0~9999RPM)0(not set)

 

Low Speed Alarm Value(0~9999RPM)0(not set)

 

Over Speed Alarm Value(0~9999RPM)9999(not set)

 

Over Speed Trouble Value(0~9999RPM)9999(not set)

 

Low Oil Pressure Trouble Value(50~300Kpa)0(not set)

 

Low Oil Pressure Alarm Value(50~300Kpa)0(not set)

 

High Temperature Alarm Value(70~160?)9999(not set)

 

High Temperature Trouble Value(70~160?)9999(not set)

 

Control Relay Output:

 

Throttle Control Output

 

Start Control Output

 

DC Charger Excitation Output

 

Idle Control Output

 

Generator Set Normal Operation

 

Generator Set Alarm

 

Generator Set Trouble

 

Trouble Alarm and Stop:

 

Charge Fail Alarm

 

High Voltage Alarm/Trouble Stop

 

Low Voltage Alarm/Trouble Stop

 

Over Current Alarm/Trouble Stop

 

Low Speed Alarm/Trouble Stop

 

Over Speed Alarm/Trouble Stop

 

Low Oil Pressure Alarm/Trouble Stop

 

High Temperature Alarm/Trouble Stop

 

Fail to start Trouble

 

Emergency Stop

 

Fail to Stop Trouble

 

Back-up Alarm/Trouble Stop

 

Exterior Dimensional Drawing:

 

Operating Panel W205mm?H156mm

 

Installation Hole Size W186m?H137m

 

Thickness D58.5mm(before connection)

 

Other Parameters:

 

DC Power Supply

 

Voltage Range:8~35V continuous

 

...