NYY -J/-O power cable
1.copper(cu)conductor
2.PVC insulated PVC sheathed
3.0.6-1kv
NYY -J/-O power cable
The cable meets the standards of GB/T12706 or IEC60502.It is suitable to be installed in the power line with rated voltage of 0.6-1kv for transmitting electricity
copper(cu) conductor,PVC insulated PVC sheathed power cable
Detailed specification:
PVC INSULATED PVC SHEATHED POWER CABLENominal Cross-sectional Area mm² | Nominal Thickness of insulation mm | Nominal Thickness Of sheath mm | Approx. Overall Diameter mm | Max.current rating at circumstance Temperature 25[A] | Approx.weight of Completed cable Kg/km | ||||
Laid in the air | Laid underground The thermal resistivity Of the soil g=80[.cm/w] | ||||||||
cu | al | cu | al | cu | al | ||||
1.5 | 0.8 | 1.4 | 5.8 | 24.4 | - | 36.0 | - | 67 | 57 |
2.5 | 0.8 | 1.4 | 6.2 | 33.9 | 25.4 | 47.7 | 37.1 | 81 | 65 |
4 | 1.0 | 1.4 | 7.0 | 43.5 | 32.9 | 64.7 | 49.8 | 107 | 82 |
2x25 | 1.2 | 1.8 | 22.0 | 113.4 | 87.9 | 138.9 | 107.1 | 789 | 466 |
2x35 | 1.2 | 1.8 | 24.2 | 131.4 | 100.7 | 165.4 | 127.2 | 1005 | 557 |
3x25 | 1.2 | 1.8 | 23.3 | 98.6 | 76.3 | 121.9 | 92.2 | 1040 | 511 |
3x35 | 1.2 | 1.8 | 25.7 | 119.8 | 92.2 | 149.5 | 114.5 | 1347 | 630 |
3x4.0+1x2.5 | 1.0 | 1.8 | 14.2 | 30.7 | 23.3 | 40.3 | 30.7 | 285 | 195 |
3x6.0+1x4.0 | 1.0 | 1.8 | 15.4 | 40.3 | 30.7 | 50.9 | 39.2 | 376 | 240 |
4x4.0 | 1.0 | 1.8 | 13.8 | 498 | 22 | 37 | 28 | 30 | 201 |
4x6.0 | 1.0 | 1.8 | 14.9 | 28 | 28 | 46 | 36 | 399 | 251 |
3x4+2x2.5 | 1.0 | 1.8 | 15.8 | 34 | - | 44 | - | 339.7 | 234.9 |
3x6+2x6 | 1.0 | 1.8 | 17.5 | 43 | - | 56 | - | 452.2 | 291.7 |
3x10+2x6 | 1.0 | 1.8 | 20.2 | 60 | - | 75 | - | 667.1 | 401.2 |
4x4+1x2.5 | 1.0 | 1.8 | 16.7 | 34 | - | 44 | - | 366.6 | 252.1 |
4x6+1x4 | 1.0 | 1.8 | 18.1 | 43 | - | 56 | - | 476.9 | 304 |
4x10+1x6 | 1.0 | 1.8 | 20.9 | 60 | - | 75 | - | 720.4 | 427.8 |
PVC insulated PVC sheathed power cable
Type,description and application
Type of PVC Cable | Type of flame retardant PVC cable | Description | Application |
V(L)V | ZC-V(L)V ZB-V(L)V ZA-V(L)V | PVC Insulated PVC Sheathed power cable | For laying indoors, in tunnels and in ducts, unable to bear external mechanical forces |
V(L)V22 | ZC-V(L)V22 ZB-V(L)V22 ZA-V(L)V22 | PVC Insulated PVC Sheathed Steel tape armoured power cable | For laying indoors, in tunnels and in ducts, able to bear external mechanical forces |
V(L)V32 | ZC-V(L)V32 ZB-V(L)V32 ZA-V(L)V32 | PVC Insulated PVC Sheathed steel wire armoured power cable | For laying indoors, in shafts and in water, able to bear moderate pulling forces. |
Specifications
NO. Of cores:1-5 cores. | Nominal cross-sectional area:1.5-630mm |
More detailed specification,please feel free to contact us.