1.AAC Conductor used as Overhead Power Transmission and Distribution Line
2. IEC61089, BS215 part1, DIN48201 part5, ASTM B231

1) standard:  IEC61089, BS215 part1, DIN48201 part5, ASTM B231, BS EN50182

 

USA Sizes-ASTM  B 231

 

Code

name

Total Area 

Stranding and Wire diameter

Approximate

Overall diameter

Linear

Mass

Nominal

Breaking load

Maximum

Resistance

At 20

AWG or MCM

mm²

mm

mm

Kg/km

daN

Ohm/km

Peachebell

6

13.29

7/1.554

4.67

37

249

2.1692

Rose

4

21.16

7/1.961

5.89

58

396

1.3624

Iris

2

33.61

7/2.474

7.42

93

597

0.8577

Pansy

1

42.39

7/2.776

8.33

117

732

0.6801

Poppy

1/0

53.48

7/3.119

9.36

147

873

0.5390

Aster

2/0

67.42

7/3.503

10.51

186

1100

0.4276

Phlox

3/0

85.03

7/3.932

11.80

234

1347

0.3390

Oxlip

4/0

107.23

7/4.417

13.26

296

1698

0.2688

 

  

British Sizes-BS215-1  

 

Code 

Name

Nominal

Aluminium

Area

Stranding

And wire

diameter

Sectional

Area

Approximate

Overall

diameter

Linear

Mass

Calculate

D.C

Resistance

At20

Calculate

Breaking 

Load

Final

Modulus of 

Elasticity

Corefficient

Of  linear

expansion

 

Mm²

mm

Mm²

mm

Kg/km

Ohm/km

daN

hbar

/

Midge

22

7/2.06

23.33

6.18

64

1.227

399

5900

23x106

Aphis

25

7/3.35

26.40

7.2

73

1.081

411

5900

23x106

Gnat

25

7/2.21

26.8

6.6

73

1.066

459

5900

23x106

 

 

German Sizes-DIN48201

Area

Stranding and

Wire diameter

Overall

diameter

Linear

mass

Calculated

Breaking load

Calculated D.C

Resistance at 20

Nominal(mm²)

Actual(mm²)

mm

mm

Kg/km

daN

Ohm/km

16

15.89

7/1.71

5.1

44

290

1.8018

25

24.25

7/2.10

6.3

67

425

1.1808

35

34.36

7/2.50

7.5

94

585

0.8332

50

49.48

7/3.00

9.0

135

810

0.5786

50

48.36

19/1.80

9.0

133

860

0.5950

70

65.82

19/2.10

10.5

181

1150

0.4371

95

93.27

19/2.50

12.5

256

1595

0.3048

120

117.00

19/2.80

14.0

322

1910

0.2459

 

International Sizes-IEC 60189

 

Code 

name

Area

Number

Of wires

Diameter

Linear

Mass

Rated

Strength

D.C

Resistance

Wire

cond.

10

 

mm

mm

Kg/km

kN

Ohm/km

10

10

7

1.35

4.05

27.4

1.95

2.8633

16

16

7

1.71

5.12

43.8

3.04

1.7896

25

25

7

2.13

6.40

68.4

4.50

1.1453

40

40

7

2.70

8.09

109.4

6.80

0.7158

 

 