Welcome to B2BAGE
Triplex Service Drop
Triplex Service Drop

Minimum Order: 0
Quality/Safety Certification: 0.00


1 IEC, ASTM, DIN, BS standard
2 ISO,CCC certification
3 Response within 12 hours
4 Free Sample
5 Factory direct sale

Duplex Service Drop
1Application
Primarily used for 120volt overhead service application such as street lighting,outdoor lighting,and temporary service for construction.To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2Construction

Code*WordPhase conductorBare Neutral MessageNominal lay LengthWeight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
StrandingInsul
Thick(Mils)
Size
(AWG)
StrandingRated
Strength
(lbs.)
inchesXLPPOLYXLPPOLY
AAC Neutral-messenger
Pekingese61456756310.3661618570
Collie67456756310.3664648570
Dachshund41454788110.36929211590
Spaniel47454788110.36969611590
Doberman274527135014.88147147150120
Malemute1/09601/07199014.88234234205160

Triplex Service Drop
1Application
Used to supply power,usually from a pole-mounted transformer,to the user's service head where connection to the service entrance cable is made.To be used at voltage of 600 volts phase-to-phase or less and at conductor temperature not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2Construction

Code*WordPhase conductorBare Neutral MessageNominal lay LengthWeight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
StrandingInsul
Thick(Mils)
Size
(AWG)
StrandingRated
Strength
(lbs.)
inchesXLPPOLYXLPPOLY
AAC Neutral-messenger
Pateela67456756314.881031038570
Oyster47454788114.8815415411590
Clam274527135020.58233233150120
Murex1/07601/07199020.58374374205160
Purpura1/09601/07199020.58368368205160
Nassa2/07602/07251025.42462462235185
Melita3/017603/019331029.97562562275215
Portunus4/018604/019402029.97696696315245
Nannynose336.41960336.419614638.7911181118420325
 

Quadruplex Service Drop
1Application
Used to supply 3-phase power,usually from a pole-mounted transformer,to the user's service head where connection to the service entrance cable is made.To be used at voltage of 600 volts phase-to-phase or less and at conductor temperature not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2Construction

Code*WordPhase conductorBare Neutral MessageNominal lay LengthWeight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
StrandingInsul
Thick(Mils)
Size
(AWG)
StrandingRated
Strength
(lbs.)
inchesXLPPOLYXLPPOLY
AAC Neutral-messenger
Clydessdale41454788120.5819819810080
Pinto47454788120.5821121110080
Mustang274527135025.42318318135105
Criollo1/09601/07199025.42503503180140
Percheron2/011602/07251029.97619619205160
Hanovarian3/017603/019331035.18764764235185
Oldenburg4/018604/019402035.18945945275210
Lippizaner336.41980336.419614638.7915191519370280
 

NOTE:

*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun.

Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.