Welcome to B2BAGE
Duplex Aluminum Service Drop Cable
Duplex Aluminum Service Drop Cable

Minimum Order: 0
Quality/Safety Certification: 0.00


Service Drop Cable for Power tranmission, used for rebuilding of urban and forest regions.

Applications:

To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75°C maximum.

 

Construction:

Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.

 

Standards:

B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.

B-231 Aluminum Conductors, Concentric-Lay-Stranded.

B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).

B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.

B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).

Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

Code

Word

Phase Conductor

Bare Neutral Messenger

Weight Per 1000 ft. (lbs.)

Allowable Ampacity+

Size (AWG)

Strand- ing

Insul. Thick. (mils)

Size (AWG)

Strand- ing

Rated Strength (lbs.)

XLP

POLY

XLP

POLY

AAC NEUTRAL-MESSENGER

Pekingese

6

1

45

6

7

563

61

61

85

70

Collie

6

7

45

6

7

563

64

64

85

70

Dachshund

4

1

45

4

7

881

92

92

115

90

Spaniel

4

7

45

4

7

881

96

96

115

90

Doberman

2

7

45

2

7

1350

147

147

150

120

Malemute

1/0

9

60

1/0

7

1990

234

234

205

160

* Code Words For XLP Insulated Products Are Formed By Adding "/XLP" to the Conventional Code Words Above (e.g.-Chihuahua/XLP).+ Conductor Temperature of 90°C For XLP, 75°C For Poly; Ambient Temperature of 40°C; Emissivity 0.9; 2 ft./sec. Wind In Sun.

 

Code Word

Phase Conductor

Bare Neutral Messenger

Weight Per 1000 ft. (lbs.)

Allowable Ampacity

Size (AWG)

Strand- ing

Insul. Thick. (mils)

Size (AWG)

Strand- ing

Rated Strength (lbs.)

XLP

POLY

XLP

POLY

ACSR NEUTRAL-MESSENGER

Setter

6

1

45

6

6/1

1190

72

72

85

70

Shepherd

6

7

45

6

6/1

1190

75

75

85

70

Eskimo

4

1

45

4

6/1

1860

110

110

115

90

Terrier

4

7

45

4

6/1

1860

115

115

115

90

Chow

2

7

45

2

6/1

2850

176

176

150

120

Bull

1/0

9

60

1/0

6/1

4380

280

280

205

160

* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

 

Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.