UYS Series of Cross-linked Ethylene-tetrafluoroethylene Insulated  Cables

Minimum Order: 0
Quality/Safety Certification: 0.00


They can be applied in various fields, such as space, navigation, electronic apparatus and instrument and other military fields.

1.

(1) Special structure

(2)Small in size

(3) Light in weight

(4) Flame resistance

(5) Resistant to chemical liquid corrosion

(6)High and low temperature resistant

(7) Excellent anti-radiation performance

(8) Excellent mechanical strength and crack resistance

(9) Easy to operate

(10) High reliability

(11)Features and parameters

a)Electrical property                               c)Combustion property             

Insulation breakdown strength0.25mm27KV     Oxygen index%       40

volume resistanceΩ-cm       10             Flame spread times     0

surface resistanceΩ-cm       5×10           Flame spread lengthmm 57

permittivity 1KHz           2.7

Power loss factors1KHz      0.001              d)Thermal property

Insulation resistanceMΩ-km   1500      Test of Cross linking degree300,7h pass

                                Resistance to thermal shock 230-55    pass  

High temperature take-up300,2h  pass

b)Physical property                   Low temperature bending-65,4h  pass

Tensile strengthN/mm   41-55              e)Chemical resistance

Elongation ratio%                         Water absorption%         0.3

Inner insulation         125        Hydrolytic stability           unhydrolyzed

The whole                75         Solution soaking                      Pass

2,the standard of the products

Q321283KDH03-2006AS-22759/3235/4146

3. 

 UYS: 

Code for series: cross-linked ethylene-tetrafluoroethylene insulated wires and cables

 Rated voltage: 1-600V

 X 

Conductors structure: 0: no shielding, no sheath; 1: round woven shielding with sheath; 2: round woven shielding without sheath3: no shielding, with sheath;

X  

Insulation structure: 1: single layerlight2: double layer

Number of conductor: expressed by 10

 X 

Conductor material 1: tin-plated copper core2: silver-plated copper core

X AWG-X/X--X

Sheath colorexpressed in digits

Insulation color: Every wires color is expressed in digit

SWG of Conductors

                                                                                                                        

4. The insulation and the sheath's code of color

Color  Black  Brown  Red  Orange  Yellow  Green  Blue  Purple  Grey  White

                                                                                                                                          

Code    0           1       2         3           4         5       6        7        8        9

5.tinned conductor: 150°C                          silver-quit conductor: 200°C          600V

                    AWG    30    28    26    24   22    20   19   18   16   15  14  13  12

                                    

Cross section mm2    0.06  0.08 0.14 0.20 0.35 0.50 0.75 1.0  1.2 1.5 2.0 2.5 3.0

Note: Wires and cables of other cross section and conductor structureS are available according to customers special requirements.