DIN rail power distribution/distributor
anti-interference.
characteristically SPD function, lightening-protection
width: 12mm
R7D series analog lightening-protection power distributors, used for industrial automation system, supply power to the two-wire system instrument and receive 4 ~ 20mA output signal outputed by on-site instruments, then isolate it and transform to DCS/PLC. It realized the matching of signal types, signal amplification, isolation and anti- interference, etc. between industrial on-site instruments and DCS/PLC. Products of this series characteristically have SPD function, which can efficiently absorb and release the surge energy produced by (external) input induction lightening. Moreover, this product can work as 4~20 mA signal isolator through different connections. It contains a variety of combination forms like one-input & one-output, one-input & two-output, two-input & two-output, etc. The width of this shell is only 12mm, which satisfies the high-density requirements of on-site installation.
General specifications | |||
Construction | Ultra-thin terminal connections | Protection grade | IP20 |
Connect | Phoenix terminals M3 screws | Mounting | EN60715 standard 35mmDIN guide |
Wire diameter | 0.2-2.5mm2 | Dimensions | W12 x H95 x D110 mm |
Tightening | 0.5-0.6Nm | Weight | probably 100g |
Housing material | Fire resin |
|
|
Input signal specifications | |
Input signal range | 4~20mA, 0-20mA, 1-5V, 0-5V, 0-10V etc. |
Input resistance | Current signal input: ≤60W |
| Voltage signal input: ≥500KW |
Absolute maximum input | Current signal: ≤200mA (with over-current protection) |
| Voltage signal: ≥30V (with over-voltage protection) |
Isolation power | no-load 24VDC±5%, 20mA output ≥ 20VDC |
Isolation power overload | ≤200mA (with over-current/short circuit protection) |
Output signal specifications | |
Output signal range | 4~20mA,0~20mA,1~5V,0~5V,0~10V etc. output signal types |
Output signal resistance
| 0/4~20mA output: 0~550W (with short circuit protection) |
| 0~10mA output: 0~1100W (with short circuit protection) |
| 0/1~5V output:≥500KW (with short circuit protection) |
| 0~10V output: ≥1MW (with short circuit protection) |
Typical application:
Ø Field may suffer attack of induction lightening surge.
Ø Field where two-wire instruments need distribution power.
Ø Field existing grounding potential difference.
Ø Field existing heavy electromagnetic interference.
Ø Protecting DCS or PLC system.
Signal need to be distributed in two roads.
If you have any queries, please feel free to contact with us.