Welcome to B2BAGE
Mining Explosion Protection High Voltage Vaccum Power Distribution Device
Mining Explosion Protection High Voltage Vaccum Power Distribution Device

Minimum Order: 0
Quality/Safety Certification: 0.00


with the protective functions of over loading, short-circuit, current leakage , insulation monitoring , over voltage ,low vol

Purpose

The mining explosion-proof(permanent magnet type)high-voltage vacuum power distribution equipment  is suitable to coal mine well with mixed explosive gas containing methane and coal dust.

In the power supply system of AC 50 Hz , rated voltage 10K V,6KV,3.3KV,rated current 630A,the product can control and protect the power supply system and start high voltage motor not frequently. The product has four types a,b,c,d to meet the usage of power receiving,Inter-connection, feeding,inter-coupled and direct control.

 

Technical Features

1.with the microcomputer integrated monitoring device ,English backlit LED display,

   displaying  voltage and three phase current actual time;

2.disjunction primary components are composed of spring high voltage vaccum circuit breaker;

3. with the protective  functions  of over loading, short-circuit, current  leakage ,

    insulation monitoring , over voltage ,low voltage and three-phase imbalance .

4. with the function of optional grounding (current leakage) 

5. with the function of KWH measurement;

6.configured with devices of  reliable machinery locking, electrical locking,

   remote control opening,  emergency opening, to make sure safe and reliable;

7.with the standard RS485 communication interface, configured in  KJ254  mining power

    monitoring system  to achieve the automation of  power distribution device and functions of            remote gauging, remote control, remote adjustment and so on. It also has the functions

   of opening –closing remotely and meter reading remotely to achieve that there is no

   need worker on duty in power substation.

Technical Data

Type

BGP9L- /3.3G

BGP9L- /6G

PBG- /10

Rated Current(A)

50,75,100,150,200,

300,400,500,630

50,75,100,150,200,

300,400,500,630

50,75,100,150,200,

300,400,500,630

Rated Voltage(KV)

3.3

6

10

Breaking Capacity(MVA)

100

100

100

Breaking Current(KA)

12.5

12.5

12.5

2Seconds Thermal Stabilization  Current(KA)

12.5

12.5

12.5

Mechanical Life (Unit)

10000

10000

10000

Times of operating over voltage

<3times of peak of phase voltage

<3times of peak of phase voltage

<3times of peak of phase voltage

 

 