HS-600II Infusion Pump
HS-600II Infusion Pump

Minimum Order: 0
Quality/Safety Certification: 0.00


Infusion Pump
Rate Mode, Time Mode, Body Weight Mode.
Double CPU Accurate Injection
Flow rate range: 1.0 ml/h-2000.0 ml/h.

HS-600II Infusion Pump

 

Function and Features

Three kinds of modes: Rate Mode, Time Mode, Body Weight Mode.

Unique door free structure: Avoiding problems of pump stuck and fluid leakage.

Double CPU: Making the process of infusion safer and more reliable.

Accurate Injection: Precise control of the infusion rate and infusion volume.

Flow rate range: 1.0 ml/h-2000.0 ml/h.

Driven by step motor: No pulsating wave will be educed even during low-rate 

injection.

Alarm is given in the following situations: Infusion Completion, Occlusion,

 Low Battery, Air Bubble, Installation Error, Malfunction or Operation Error.

IV Set: All brands of standard IV sets are compatible.

KVO rate can be selectable according to concrete requirements from 1.0 ml/h to 5.0 ml/h.  

Wireless Module Control: When used with SK-2000I or SK-900I, the infusion information will be transferred to the Infusion Supervision System in order to ensure the patients’ safety. 

Big Color LCD.

 

Technical Parameters of HS--600II Infusion pump

 

Dimension

120×140×190 mm

 

Accumulated infusion volume

1.0~9999.0 ml

Maximum weight

2.0 kg

Infusion accuracy

±3%

Displayed information

RATE

VOL.LIMIT

∑( accumulated infusion volume)

Battery charge indicator

AC power indicator

Over

OCCL.

AIR

BED No.

Alarm function

Over

OCCL.

Low battery

IV line installation error

AIR

EMPTY

Machine malfunction

Fuse

T 2AL 250V~

KVO rate

1.0 ml/h-5.0 ml/h

Maximum power consumption

25VA, running more than 4 hours after being charged

Selectable modes

Rate mode, Time mode, Weight mode

Infusion rate range

1.0-2000 ml/h

Rate mode

1.0~2000.0 ml/h

Bolus

Rate:≤1000.0 ml/h

Bolus: 1000.0 ml/h

Time mode

Volume limit: 0.1~999.9ml  Time: 1~2000 minutes

Operation conditions

Environment temperature 5°C~40°C, air pressure 86kPa~106kPa, relative humidity ≤80%

Body Weight mode

Drug limit: 1.0~999.9 mg, Volume limit: 0.1~999.9 ml. Weight: 0.1~300.0 kg, Dose: 0.1~9999.9

Selectable unit: mg/kg/h, ug/kg/min

Electrical Safety

Comply with EN60601-1 for medical equipment and EN60601-2-24

Battery

Rechargeable lithium polymer battery, 7.4V, 1600 mA

Applicable infusion sets

All standard IV sets

Storage

Environment temperature-20~55°C, air pressure 50~106kPa, relative humidity ≤95%