High Frequency Mobile C-arm SystemOrthopedics: restore bone translocation, reset, fixing
Surgery: taking foreign bodies out of
High Frequency Mobile C-arm SystemOrthopedics: restore bone translocation, reset, fixing
Surgery: taking foreign bodies out of
KGW112 High frequency Mobile Surgical X ray System Features and specifications
First: Uses
Orthopedics: restore bone translocation, reset, fixing
Surgery: taking foreign bodies out of the body, cardiac catheterization, implantable pacemakers, interventional treatment, some of angiography and local photography etc.
Second: Features
A new frame design and compact appearancethe use of more security for unique base electric auxiliary support arm design,A unique hand-held controller design, operation more convenientwith high-quality Combination high frequency high-voltage X-ray generator, thus greatly reducing the amount of X-ray irradiationWith a perspective KV, MA automatic tracking feature, so that the image brightness, sharpness automatically in the best conditionadopt Toshiba image intensifier, the quality is stable and reliable, a good image clarityMedical Progressive output high-resolution television system,,8 image storage function, the image clearer, easier to use,Installation of dense grain grids, further enhance image definition
Third: basic configuration
New (with power-assisted rack support arm) C-Arm Host 1 setCombined high-frequency high-voltage X-ray generator and high-frequency inverter power supply 1 setToshiba 9 inch image intensifier 1 setImport Ultra-low-light digital camera 1 pcs dense grain grids 1 setElectric adjustable limit beam splitter 1 setCCU in the high-definition progressive output control system 1 set14-inch high-definition medical monitor 2 pcsUnique hand-held controller I set New TV car 1 set
KGW112 High frequency Mobile Surgical X ray System Performance and Parameter
Category | Project | Content |
Fluoroscopy Capacity | Photography max rated capacity | 3.5KW |
Perspective max rated capacity | Tube current 4 mA ,Tube voltage 110 kv | |
automatic fluoroscopy | tube voltage 40 kv,110kv,adjust automatically tube current :0.3mA~~4mA adjust automatically | |
Manual Fluoroscopy | tube voltage 40 kv,110kv, continuous tube current :0.3mA~~4mA continuous | |
pulse frequence | tube voltage 40 kv,110kv, continuous tube current :4.1mA~~8mA continuous | |
Photography tube voltage, tube current mAs | 40KV~110KV,1~125 mAs | |
Plateholder size | 200mmx250mm(8”x10”)or250mmx300mm(10”x12”)250mmx300mm(10”x12”) | |
X ray tube | X ray tube special for High frequency | Fixed anode rotary anode x-ray tube with 2 focus :large focus:1.5,s mall focus :0.6;inverter frequency :40KHZ, thermal capacity :150KJ(200Khu) |
Video system | Image intensifier | Toshiba 9 inch image intensifier |
CCD Camera | Japan imported ultra-low-light digital camera | |
Monitor | Horizontal 1000 lines and vertical 800 lines,bandwidth 12.5mHz ,50bit, Image/sec:25 | |
CCU (central control) | Scan line by line,recursive filter,K=8,8images storage,image upright, horizontal image, positive & negative image,LIH(last image freeze), and image patching | |
structure | Direction wheel | ±90°revolution,can change the moving direction of the unit |
Ascending & descending range of pillar | ≥400mm | |
C-arm | Forward and backward movement:200mm; Revolution around horizontal axis : ±180°;Revolution around vertical axis: ±15°,Slip on orbit : 120°(+90°~-30°) |