Welcome to B2BAGE
CHVL Series Condensing Unit
CHVL Series Condensing Unit

Minimum Order: 0
Quality/Safety Certification: 0.00


Specification of CHVL Series Condensing Unit
1. The refrigerant charge must be controlled strictly.

CHVL Series Condensing Unit

Specification of CHVL Series Condensing Unit

Model

CHVL-13E

CHVL-16E

CHVL-23E

CHVL-29E

CHVL-41E

Nominal Input (w)

700

900

1200

1400

2100

power Supply

220V/50Hz

refrigerant(max. limit kg)

R22(1.2)

R22(1.5)

R22(2.0)

R22(2.5)

R22(3.5)

start-up current (A)

22

27

38

42

66

Max. Load Current (A)

4

5.1

6.5

7.7

11.2

Evaporating Temp.

-40 ~ -5

Ambient Temp.

0 ~ 40

Model of Compressor

HRVL-13E

HRVL-16E

HRVL-21E

HRVL-29E

HRVL-41E

Condenser

Style

Fin Tubes

Fan motor

(mm)

300

300

300

350

400

Diameter of Fan

Air Flow

1300

1530

1530

1800

3000

(m 3 /hr)

Pipe mm

Gas Inlet

12.7

15.88

Liquid Outlet

9.52

Outline Dimension

Length(mm)

560

580

610

630

Width(mm)

470

580

540

610

Height(mm)

365

445

545

Refrigeration Capacity

Evaporating Temp.()

Refrigeration Capacity W ( Kcal/h )

Condensing Temp.: 45 Ambient Temp.: 32

-40

410(355)

505(434)

670(580)

845(730)

1350(1160)

-35

532(458)

650(560)

820(709)

1033(893)

1684(1444)

-30

656(563)

800(688)

1005(870)

1266(1096)

2080(1785)

-25

793(682)

969(833)

1240(1070)

1562(1348)

2550(2190 )

-20

969(833)

1183(1017)

1500(1295)

1845(1593)

3100(2670)

-15

1164(1000)

1421(1223)

1840(1590)

2263(1956)

3740(3210)

-10

1416(1217)

1728(1486)

2125(1825)

2614(2245)

4490(3860)

-5

1672(1438)

2042(1756)

2440(2095)

3010(2577)

5350(4600)

Wiring Capacity

Leakage Protector

Rated Current

10

15

20

( A )

Leakage Current

30

( mA )

Wire Diameter

Within 10m

2

Within 20m

2

2.5

(mm 2 )

Within 30m

2

2.5

Notes

1. The refrigerant charge must be controlled strictly. The Maximize limitation of charging is listed in the table.

2. Diameter of the suction and evaporating pipes should be decided by oil circulation and reconfirmation of gas speed.

3. The diameter of pipes must guarantee the gas speed of 3.8m /s through horizontal pipes and 7.6m /s through vertical ones.

4. The single sided pipe length is 10m; with height difference should be within 3m.


Related Products
Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.