General

A thermal relays connected with a contactor breaks the circuit in order to isolate the motor in case of over load or phase is cut out. The contactor with a thermal relay becomes a much useful device. That protects the consumer against the over current, also protects the contactor against the effects or over heat.


Full fill following standard

IEC60947-4-1


How Thermal Relay Works

Each phase of thermal overload relay is related to over current angle. Bimetals pushes the differential bar and opens the circuit when it is heated. Only two bimetals operate when one phase is cut out and the over current angle operates much rapidly due to over current. The mechanism of the thermal relay compensates changes of ambition temperature and prevents the relay against effects of temperature changes. The average value of opening characteristic of thermal current relay under not condition operation is smaller than cold condition. In other words, cold relay open later than hot relay approximately ratio at the determined current. That is important about safety of for the relay and protected device. The relay under hot condition and over loaded 1.5 times should break circuit within 2 min. for motors according to IEC60947-4-1.

Below is selection form for DTH Series Thermal Relay:

TypeNominal Current(A)Setting Range(A)For ContactorCase Qty.(Pcs)
DTH5-22-0.140.140.1~0.16CJX5-9~22100
DTH5-22-0.210.210.16~0.25CJX5-9~22100
DTH5-22-0.330.330.25~0.4CJX5-9~22100
DTH5-22-0.520.520.4~0.63CJX5-9~22100
DTH5-22-0.820.820.63~1CJX5-9~22100
DTH5-22-1.31.31~1.6CJX5-9~22100
DTH5-22-2.12.11.6~2.5CJX5-9~22100
DTH5-22-3.33.32.5~4CJX5-9~22100
DTH5-22-554~6CJX5-9~22100
DTH5-22-6.56.55~8CJX5-9~22100
DTH5-22-7.57.56~9CJX5-9~22100
DTH5-22-8.58.57~10CJX5-9~22100
DTH5-22-11119~13CJX5-9~22100
DTH5-22-151512~18CJX5-9~22100
DTH5-22-191916~22CJX5-9~22100
 
DTH5-40-554~6CJX5-32/4050
DTH5-40-6.56055~8CJX5-32/4050
DTH5-40-7.57.56~9CJX5-32/4050
DTH5-40-8.58.57~10CJX5-32/4050
DTH5-40-11119~13CJX5-32/4050
DTH5-40-15158CJX5-32/4050
DTH5-40-191916~22CJX5-32/4050
DTH5-40-222218~26CJX5-32/4050
DTH5-40-303024~36CJX5-32/4050
DTH5-40-343428~40CJX5-32/4050
 
DTH5-85-8.58.57~10CJX5-50~8550
DTH5-85-11119~13CJX5-50~8550
DTH5-85-151512~18CJX5-50~8550
DTH5-85-191916~22CJX5-50~8550
DTH5-85-222218~26CJX5-50~8550
DTH5-85-303024~36CJX5-50~8550
DTH5-85-343428~40CJX5-50~8550
DTH5-85-424234~50CJX5-50~8550
DTH5-85-555545~65CJX5-50~8550
DTH5-85-656554~75CJX5-50~8550
DTH5-85-747463~85CJX5-50~8550

Feature: DLR2N Series Thermal relay aslso called Overload relay to protect Contactor which is working with.

Ads by Google

Related Searches


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.