widely applied to military and aerospace
ENVIRONMENTAL CONDITIONS:
ITEM | DATA |
Environmental temperature | -55°c~125°c |
Low pressure | 0.67kPa~0.27kPa |
Relative humidity | 40°c±2°c, 92%~98% |
Sinusoidal vibration | 10Hz~2000Hz, 196m/s2 |
Impact | 735m/s2, 6ms |
Acceleration | 735m/s2 |
ORDERING SYMBOL | Q/RY.J01118-2006: 2JS10.5-1 Note: The accuracy of time delay and mounting means should be indicated when ordering. |
MAIN TECHNICAL DATA:
ITEM | DATA | ITEM | DATA |
Type of time delay | Type 1(action delay) | Life | 1×105 times or 50h |
Range of working voltage | 18Vd.c.~32Vd.c. | Transient power off | 50μs |
Rated working voltage | 28Vd.c. | Dielectric withstanding volt. | 500Vr.m.s., 60s, 1mA |
Input current | ≤12mA | ||
Output load | 28Vd.c., 0.5A(resistance) | Insulation resistance | 1000MΩ, 500Vd.c. |
Output form | 2 groups of normally open | Leakage rate | ≤1×10-1Pa.cm3/s |
The accuracy of time delay | ±2% | Weight | ≤12g |
Range of time delay | 0.05s~500s | Outside measurement | 20.5mm×10.5mm×7.8mm |
Recirculation time | 50ms | Mounting means | A(0), C1(1) |