Welcome to B2BAGE
85~264VAC by switch 48v 60w uninterruptible power supply
85~264VAC by switch 48v 60w uninterruptible power supply

Minimum Order: 0
Quality/Safety Certification: 0.00


48v 60w uninterruptible power supply
1. 85~264VAC by switch
2. protections overload/over voltage/shortcircuit
3. CE ETS EMCUL

85~264VAC by switch 48v 60w uninterruptible power supply with CE Rohs UL ETS EMC

1. Specification:

DC output: 48V 1.3A load regulation: 0.5%ripple&noise: 150mV efficiency(Typ.): 81%                    AC input voltage range        85~264VAC selected by switchinput frequency               47~63HzInrush current                cold start,20A/115V,40A/230Vinput leakage current        <0.7mA/230VACLine regulation(full load)     <=+-0.5%Output voltage adjust range     +-10%Output overload protection      110~150%Output over voltage protection     115~150%Withstand voltage               I/P -O/P:3.0KVAC/1min     I/P -F/G:1.5KVAC/1min    O/P-F/G:0.5KVAC/1minRise time                       50ms@full load(typical)Hold up time                    20ms@full load(typical)Operating temp.& humidity       -10°C~+50°C,20%~93%RH(non condensing)Storage temp.&humidity           -20°C~+85°C, 20%~95%RH(non condensing)Safety standards                    GB4943,UL60950,EN60950EMC standards                  GB9254,EN55022 class B, EN55024  EN61000-3-2,3, en61000-4-2,3,4,5,6,8,11Cooling method                convectionUniversal AC input/full rangeProtection: overload/ over voltage/ short circuitapprovals: UL, ETS/EMC/CE100% full load burn-in testhigh reliability2 years warrantysize:     160x98x39(mm)

2  Dimensional drawings:

     

3. The package of one product:

 

 

4. The partial enlarged detail:

 

  

 

5. Safety Precautions:

Definition of AC input: 

Allocation of neutral line: For power supplies with power factor 0.4~0.6, when several sets of power supplies used in 3-phase, 4-line input system, the current of the neutral line cannot be offset because of the distortion of the input current wave. Therefore, in normal circumstances, we suggest that the neutral line should be allocated as 1.5~2 times the cross-sectional area of the hot line.  Leakage current: When several sets of power supplies connected to ground at the same place, the leakage current will be redoubled accordingly. Care must be taken to avoid electric shock. Battery charger: Most of our single output power supplies above 100W can be directly used as battery charger by means of floating charge (constant current limiting).

    Four typical ways of series-parallel connection as follows: 

 

 

Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.