Welcome to B2BAGE
Switching Power Supply 50W Single phase output S-50-24
Switching Power Supply 50W Single phase output S-50-24

Minimum Order: 0
Quality/Safety Certification: 0.00


switching power supply,switch power supply,DC power supply
Protection:Over load,over voltage,short circuit
Professional export

switching power supply,switch power supply,DC power supply
Protection:Over load,over voltage,short circuit
Professional export

  

 


Specification
S-50-5S-50-12S-50-15S-50-24
DC output voltage5V12V15V24V
Output voltage error (Note2)±2%±1%±1%±1%
Rated output current10A4.2A3.4A2.1A
Output current rage0-10A0-4.2A0-3.4A0-2.1A
Wave and noise(Note3)75mVp-p100mVp-p100mVp-p100mVp-p
Inlet stability(Note4)±0.5%±0.5%±0.5%±0.5%
Load stability(Note5)±1%±0.5%±0.5%±0.5%
DC output power50W50.4W50.4W50.4W
Efficiency71%78%78%82%
Adjustable range for DC voltage±10,-5%±10%±10%±10%
AC input voltage range85∼132VAC/170∼264VACselected by switch
Input current1.3A/115V 0.65A/230V
AC impulse currentCold-start current 18A/115V 36A/230V
Leakage current<0.5mA/240VAC
Overload protection

105%∼150%TypeTOLDBACK Reset: auto recovery

Over-voltage protection 
High-temperature protection 
Temperature coefficient±0.03%(0∼50)
Setup rise hold up time200ms,100ms,30ms
Vibration10∼500Hz,2G 10min./1cycle,Period for 60min,Each axes
Withstand voltage

Input and output interval1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistanceInput and output interval,Input and enclosure,Output and enclosure0500VAC/100M Ohms
Working temperature and humidity-10∼+60,20%∼90%RH
Store temperature and humidity-20∼+85,10%∼95RH
Overall dimension159*97*38mm
Weight0.5Kgs
Safety standardsMeet UL1012
EMC standards 
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adoptingA12double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2311must be knocked down.

 

 