Switching Power Supply 50W Single phase output S-50-24
Minimum Order: 0
Quality/Safety Certification: 0.00
switching power supply,switch power supply,DC power supply
Protection:Over load,over voltage,short circuit
Professional export
switching power supply,switch power supply,DC power supply
Protection:Over load,over voltage,short circuit
Professional export
Specification | S-50-5 | S-50-12 | S-50-15 | S-50-24 |
DC output voltage | 5V | 12V | 15V | 24V |
Output voltage error (Note2) | ±2% | ±1% | ±1% | ±1% |
Rated output current | 10A | 4.2A | 3.4A | 2.1A |
Output current rage | 0-10A | 0-4.2A | 0-3.4A | 0-2.1A |
Wave and noise(Note3) | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet stability(Note4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability(Note5) | ±1% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 50W | 50.4W | 50.4W | 50.4W |
Efficiency | 71% | 78% | 78% | 82% |
Adjustable range for DC voltage | ±10,-5% | ±10% | ±10% | ±10% |
AC input voltage range | 85∼132VAC/170∼264VACselected by switch | |||
Input current | 1.3A/115V 0.65A/230V | |||
AC impulse current | Cold-start current 18A/115V 36A/230V | |||
Leakage current | <0.5mA/240VAC | |||
Overload protection | 105%∼150%TypeTOLDBACK Reset: auto recovery | |||
Over-voltage protection | ||||
High-temperature protection | ||||
Temperature coefficient | ±0.03%(0∼50) | |||
Setup rise hold up time | 200ms,100ms,30ms | |||
Vibration | 10∼500Hz,2G 10min./1cycle,Period for 60min,Each axes | |||
Withstand voltage | Input and output interval1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC | |||
Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure0500VAC/100M Ohms | |||
Working temperature and humidity | -10∼+60,20%∼90%RH | |||
Store temperature and humidity | -20∼+85,10%∼95RH | |||
Overall dimension | 159*97*38mm | |||
Weight | 0.5Kgs | |||
Safety standards | Meet UL1012 | |||
EMC standards | ||||
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity 2.Error,include the setting error, line stability and load stability.(Note:5) 3.Wave test:adoptingA12double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting 4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage. 5.Load stability test: The load is from 0% to 100%,others 60%. 6.C2311must be knocked down. |