1. 5V/12V/24V output voltage;
2. can special make all kinds of data;
3. CE certificate;
4. good quality fast delivery.
Power supply S-15-12
Model Performance | S-15-5 | S-15-12 | S-15-24 |
DC output voltage | 5V | 12V | 24V |
Output voltage tolerance(Note 2) | ±2% | ±1% | ±1% |
Rated output current | 3A | 1.3A | 0.7A |
Output current range | 0-3A | 0-1.3A | 0-0.7A |
Ripple and noise(Note 3) | 50mVp-p | 50mVp-p | 100mVp-p |
Inlet stability(Note 4) | ±0.5% | ±0.5% | ±0.5% |
Load stability(Note 5) | ±1% | ±0.5% | ±0.5% |
DC output power | 15W | 15.6W | 16.8W |
Efficiency | 65% | 68% | 72% |
DC voltage adjustable range | ±10,-5% | ±10% | ±10% |
Input voltage range | 85~132VAC/170~264VAC selected by switch 47~63Hz240~370VDC | ||
Input current | 0.5A/115V 0.25A/230V | ||
Surge Current | Cold-start current 15A/115V 30A/230V | ||
Leakage Current | <0.5mA/240VAC | ||
Overload protection | 105%~150%type:pulsing hiccup shutdown Reset:auto recovery | ||
over-voltage protection | …… | ||
High temperature protection | …… | ||
temperature coefficient | ±0.02%°C(0~50°C) | ||
Start-up,rise,hold up time | 200ms,100ms,30ms | ||
shock resistance | 10~500Hz,2G 10min./1circle,Period for 60min.,Each axes | ||
Withstand voltage | Input and Output internal:1.5KvAC,input and enclosure:1.5KvAC, output and enclosure:0.5KvAC | ||
Insulation Resistance | Input and Output internal: input and enclosure,output and enclosure:500VDC/ 100M/Ohms | ||
work temperature/humidity | -10°C~+60°C(Refer to output derating curve),20%~90%RH | ||
storage temperature /humidity | -20°C~+85°C,10%~95RH | ||
Outline dimension | 99*97*35mm CASE:905 | ||
weight | 0.3Kgs | ||
Safety standards | Satisfy the requires of UL1012 | ||
EMC Standards | Satisfy the clause CLASS B of FCC PART15J | ||
Note: 1.The above parameters test conditions: 230VAC input, rated load, 25 °C 70% RH. Humidity. 2.Tolerance: includes set up tolerance, line stability and load stability (Note 5). 3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uF capacitor circuit. 4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage. 5.Load stability test: the load from 0% to 100%. |
More choice: