100% full load burn-in test
Low cost, high reliability
1 year warrabty
Colling by free air convection
The main technical parameters:
AC input voltage range----------------85-132VAC/170-264VAC 47-63HZ 240-370VDC
Input current-----------------------------3.2A/115V 1.6A/230V
AC inrush current-----------------------Cold-start current 25A/115V 50A/230V
Leakage current-------------------------<3.5mA/240VAC
DC adjustable range---------------------±10% rated output voltage
Over lade protection---------------------105-150% Cut output , automatic recovery
Over voltage protection------------------115-135%
Setup rise lold up time-------------------200ms 100ms 20ms
Withstand voltage ------------------------I/P-O/P:1.5KVAC 1minute
I/P-FG:1.5KVAC 1minute
O/P-O/P:0.5KVAC 1minute
Working temperature-------------------- -10°C~+60°C.20%-90% RH
Weight/packing-------------------------- 0.8kg .24pcs/19.2kg
Type | Output | Error | Range | Efficiency |
S-150-5 | 5V, 0-30A | ±2% | 150mV | 78% |
S-150-7.5 | 7.5V, 0-20A | ±1% | 150mV | 80% |
S-150-9 | 9V, 0-16.7A | ±1% | 180mV | 80% |
S-150-12 | 12V, 0-12.5A | ±1% | 180mV | 82% |
S-150-13.5 | 13.5V, 0-11.2A | ±1% | 180mV | 83% |
S-150-15 | 15V, 0-10A | ±1% | 180mV | 84% |
S-150-24 | 24V, 0-6.5A | ±1% | 240mV | 85% |
S-150-27 | 27V, 0-5.6A | ±1% | 240mV | 86% |
S-150-48 | 48V, 0-3.2A | ±1% | 240mV | 87% |