 50W dual output switch power supply Competitived price and high reliability 105oC Output capacitor   AC input power suitable for the world  High efficiency and low operation temperature Soft-start current can reduce the AC input impact effeciticly With short-circuit and overload protection Compact size, light weight 100% full-load burn-in test Installed with EMI filter, minimum wave

ModelD-50AD-50B
CH1CH2CH1CH2
DC output voltage5V12V5V24V
Output voltage range(Note:2)±2% +5,-8%%±2%±8%
Rated output current6A2A6A1A
Output current range1-6A0.3-2A1-6A0.2-1A
Wave and noise(Note:3)50mVp-p100mVp-p50mVp-p100mVp-p
Inlet stability(Note:4)±0.5%±1%±0.5%±1%
Load stability(Note:5)±0.5%±5%±0.5%±8%
DC output power54W54W
Efficiency73%73%
Adjustable range for DC voltageCH1; +10, -5%CH1; +10, -5%
Input current1.3A/115V0.65A/230V
AC inrush currentCold-start current 18A/115V 36A/230V
Leakage current<0.5mA/240VAC
Overload protection105%~150% Type: pulsing hiccup shutdown Reset: auto recovery
Temperature coefficient±0.03%/°c(0~50°c)ON+5V
Setup, rise , hold up time200ms,50ms, 30ms
Vibration10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltageInput and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvAC
Isolation resistanceInput and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ
Working temperature and humidity -10°c~+60°c(Refer to output derating curve), 20%~90%RH
Overall dimension159×97×38mm
Weight0.52Kgs
Safety standardsMeet UL requirement (Not apply for the mark)

Note:                                                                                                                                                                     1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer.                 

2. Error: include the setting error, line stability and load stability.(Note:5).                                                                                                                                                             3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.               

4. Inler woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.                         

5. Load stability test: The load is from 0% to 100%.                                                                                                 

6. Total output canba maxinum Current, total load can not exceed the maxium output power.