Welcome to B2BAGE
quad output switching power supply
quad output switching power supply

Minimum Order: 0
Quality/Safety Certification: 0.00


quad output switching power supply
OEM Manufacture in China;
Obtained CE and ISO9001 certificates;
High quality and favorite

quad output switching power supply

Low price and high reliability

105 degree output capacitor

AC input power suitable for the world

High efficiency and low operation temperature

Soft-start current can reduce the AC input impact effecticly

Compact size, light weight

100% full-load bum-in test

Installed with EMI filter, minimum wave.

Specification/Model

S-50-5

S-50-12

S-50-15

S-50-24

DC output voltage

5V

12V

15V

24V

Output voltage range

±2%

±1%

±1%

±1%

Rated output current

 10A

4.2A 

 3.4A

2.1A 

Output current range

 0-10A

0-4.2A

0-3.4A

0-2.1A

DC output power

 50W

50.4W

51W

50.4W

Adjustable range for DC voltage

 +10,-5%

 ±10%

 ±10%

 ±10%

AC input voltage range

85~132VAC/170~264VAC selected by switch 47~63HZ;240~370VDC

Input current

1.3A/115V 0.65A/230V

AC inrush current

Cold-start current 18A/115V 36A/230V

Leakage current

<0.5mA/240VAC

Overload protection

105%~150% Type:pulsing hiccup shutdown Reset: auto recovery

Temperature coefficient

±0.03%/°C(0~50°C)

Vibration

 10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes

Withstand voltage

Input and output internal:1.5KvAC, input and enclosure:1.5KvAC, 

Output and enclosure:0.5KvAC

Isolation resistance

Input and output internal: input and enclosure, 

Output and enclosure:500VDC/100MΩ

Working temperature and humidity

 -10°C~+60°C,20%~90%RH

Store temperature and humidity

 -20°C~+85°C, 10%~95%RH

Overall dimension

157×97×38mm

Weight

 0.5Kgs

1, With CE standards;

2, The testing condition for the parameter above is: 230VAC input, rated load, 25°C 70% RH. Temperature.

3, Error: include the setting error, line stability and load stability.

4, Wave test: adopting "A12" double wire for 20MHZ, and 0.1UF&47UF capacitor short-circuit for interrupting.

5, Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.

6, Load stability test: The load is from 0% to 100%.

Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.