Welcome to B2BAGE
30W dual output switching power supply
30W dual output switching power supply

Minimum Order: 0
Quality/Safety Certification: 0.00


30W dual output switching power supply
OEM Manufacture in China
Obtained CE ISO9001 certificates;
High quality and favorate

30W dual output switching power supply

Low price and high reliability

105 degree output capacitor

AC input power suitable for the world

High efficiency and low operation temperature

Soft-start current can reduce the AC input impact effecticly

Compact size, light weight

100% full-load bum-in test

Installed with EMI filter, minimum wave.

Product Description 

Model/Specification

D-30A

D-30B

CH1

CH2

CH1

CH2

DC output voltage

5V

12V

5V

24V

Output voltage error (Note2)

±2%

±1%

±1%

±1%

Rated output current

4A

1.3A

2.2A

1A

Output current rage

0.5-4A

0-1.3A

0-4A

0.1-1A

Wave and noise(Note3)

50mVp-p

50mVp-p

50mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±0.5%

±0.5%

±1%

Load stability(Note5)

±0.5%

±0.5%

±0.5%

±4%

DC output power

32W

75W

Efficiency

72%

74%

Adjustable range for DC voltage

CH1+10,-5%

CH1+10,-5%

AC input voltage range

85~132VAC/170~264VAC;selected by switch 47~63Hz;240-370VDC

Input current

0.86A/115V 0.45A/230V

AC impulse current

Cold-start current 18A/115V 36A/230V

Leakage current

<0.5mA/240VAC

Overload protection

105%~150% Type,FOLDBACK Pulsing hiccup shutdown Reset. auto recovery

Over-voltage protection

……

High-temperature protection

……

Temperature coefficient

±0.03%°C(0~50°C) ON+5V OUTPUT

Setup rise hold up time

200ms,50ms,30ms

Vibration

10~500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval,1.5KVAC,Input and enclosure,1.5KVAC,Output and enclosure,0.5KVAC

Isolation resistance

Input and output interval,Input and enclosure,Output and enclosure0500VAC/100M Ohms

Working temperature and humidity

-10°C~+60°C,20%~90%RH

Store temperature and humidity

-20°C~+85°C,10%~95RH

Overall dimension

129*98*35mm

Weight

0.4Kgs

Safety standards

Meet UL1012 requirement(Not apply for the mark)

EMC standards

Meet FCC Part 15J Conduction class B

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25°C 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting

Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.