50W AC DC Power Supply
Minimum Order: 0
Quality/Safety Certification: 0.00
50W AC DC Power Supply
1.MODEL: S-50
2.INPUT:110V OR 220V
3.With CE Approval
4.DIMENSION: 159*97*38mm (L*W*H)
50W AC DC Power Supply
Features:
AC input range selected by switchProtections: Short circuit/Over loadCooling by free air convectionLED indicator for power onFixed switching frequency at 27KHz
50W AC DC Power Supply SPECIFICATION:
Model No. | Output | Tol | R&N | Effi. |
S-50-5 | 5V, 0~10A | ±2% | 75mV | 71% |
S-50-12 | 12V, 0~4.2A | ±1% | 100mV | 78% |
S-50-15 | 15V, 0~3.4A | ±1% | 100mV | 78% |
S-50-24 | 24V, 0~2.1A | ±1% | 100mV | 82% |
OUTPUT
RATED POWER | 50W |
LINE REGULATION | ±0.5% |
LOAD REGULATION | ±0.5% |
SETUP, RISE, HOLD TIME | 200ms, 100ms, 20ms at full load |
OVERLOAD | 105 ~ 150% rated output power |
Protection type : Fold back current limiting, recovers automatically after fault condition is removed. |
VOLTAGE RANGE | 85 ~ 132VAC / 170 ~ 264VAC selected by switch 240 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
AC CURRENT | 1.3A/115VAC 0.65A/230VAC |
INRUSH CURRENT (max.) | COLD START 18A/115VAC 36A/230VAC |
LEAKAGE CURRENT | <1mA / 240VAC |
WORKING TEMP. | -10 ~ +60ºC |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY STANDARDS | Design refer to UL1012 |
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI CONDUCTION & RADIATION | Design refer to FCC Part15 J Conduction Class B |
MTBF | 408.3K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 159*97*38mm (L*W*H) |
PACKING | 0.444Kg; 30pcs/14.92Kg/0.0250CUFT |
Mechanical Specification: