infrared ray thermometer DT-8530
Temperature Range:- 50C~530C(-58 F~986F)
Backlight display , easy to use
CE,SGS,UKAS
infrared ray thermometer DT-8530
Package Included:
· 1x Infrared Thermometer
· 1x 9V Battery
· 1x Englisch Manual
· 1x Leather case
Modle
parameters | digital infrared thermometer for industrial use with data hold function DT-8530 |
Temperature Range | - 50°C ~ 530°C (-58 °F ~ 986°F) |
Accuracy | ±2% or 2°C |
Distance Spot Ratio | 12:1 |
Emissivity | 0.95 |
Response Time & Wavelength | 500ms & (8-14)um
|
Repeatability | ±1% or±1°C |
Resolution | 0.1°C or 0.1°F |
Storage Temperature | -20-50°C (-4-122°F) |
Operating Temperature | 0-50°C(32-122°F) |
°C °F /Selection | √ |
Data Hold Function | √ |
Auto Power Shut Off | √ |
Low Battery Indication | √ |
Laser Target Pointer Selection | √ |
Backlight Display Selection | √ |
Power | DC 9V Battery |
Product Color | Yellow + Black |
Standard Quantity Per Carton | 20pcs |
Standard Carton Size | 46.5*30*26cm |
Standard Carton Gross Weight |
7.7 kg |
measuring trigger :
to measure a temperature , point the unit at an object and pull the trigger . the temperature reading
will appear on the LCD. when the trigger is released , the reading will automatically be held on the
LCD for an additional 15 seconds . after 15 seconds , the thermometer will antomatically shut-off
to save the battery
Be sure to consider the distance-to -spot size ratio and field of view .the laser is used for an
aiming reference only .
maintenance:
blow off loose particles ,gently brush remaining debris away with a lend brush .carefully
wipe the surface with a cotton swab . the swab may be moistened with water .please don't use
solvents to clean the glass lens .
replace battey:
when the battery voltage drops below that required for reliable operation , the low
battery symbol will appear indicating it is time to replace the battery. to change the battery ,
detach the battery compartment cover by pushing the engraved pattern on the handle and pull
down .
emissivity :
emissivity is a term used to describe the engery emitting characteristics of materials .
most organic materials and painted or oxidized surfaces have a lower emissivity and give iaccurate readings . please note this during applications.
cautions :
1.keep away from electrical welders , induction heaters and EMF sources
2.when the thermometer is exposed to large or abrupt ambient temperature changes , allow 15
minutes for unit to atabilize before use .
3.do not store the thermometer in a high temperature environment .
4.store in carry case after operation to avoid contamination of optical lenses.
For more details, visit : www.olbo.cc