Minimum Order: 0
Quality/Safety Certification: 0.00
*PID Intelligent temperature controller
*CE approved
*Size:96*48*60mm
*High precision,Anti-jamming
PID Intelligent temperature controller,temperature meter(SG6)
|
| Comparing with same products at home, G-2500 Series Intellective Digital Temperature Control Meters won the markets by reasonable price and stable performance, CE has been approved, G-2500 are applied to many fields that RKC,FUJI, OMRON, SHINKO, SHIMADEN used to mount.G-2500 is cheaper over 50% than Japanese products, so competitive price and first-class after service will overcome rivals both at home and broad. |
|
|
|
| electric network and diesel engine generating system. ·Anti-jamming. Products can work normally under circumstance that RKC,FUJI, OMRON, SHINKO, SHIMADEN usually in. · Quick AT self-tuning adaptive control and high precision of temperature control. ·Manual and automatic operation can be set by panel. ·Function of input signal and filtering (filtering quotiety 0~100) ·Arrears (password) lock function.( RKC, FUJI, and OMRON is without this function). ·User of zero declination can be adjustable. ·Power output percent (SV window) can switch display. (Digital display replaced light beam display, and RKC, FUJI, and OMRON is without this function). ·Cooling output is controlled by PD (alarm 1). it adapts to water cooling, wind cooling, and adjust better than RKC, FUJI, and OMRON. ·Timer: max timer function--100 hours, and can control facility working hour ( RKC, FUJI, and OMRON is without this function). ·Power output can be limited.(can be controlled up and down) ·Alarm: 7 kinds of alarm mode can be configured freely. ·Adopting single key to work (easy to work). |
|
|
| 3. Meter's Technical Index |
|
| 1) Indication precision: ?.3%FS ? character 2) Setting precision: ?.3%FS? character 3) Input sampling cycle: 0.2 second 4) Relay Point Control Output: 250VAC 3A(block load) 250VAC 1A(Inductive load, cos=0.4) 5) No point Voltage Control Output: ( SSR drives)12VDC, Max:40mA (short circuit protection) 6) Current & voltage output: 4-20mA, load resistance Max=500 Ohm.0-10VDC, load current ≤10mA 7) Assistant power supply (feeding): 10V, 12V, 24V can be optional, load current≤20mA 8) Alarm mode: on/off mode, lag 1 (1) or 0.1 9) Alarm Output: Relay Point:250VAC 3A(resistance load) 250VAC1A(Inductive load, cos=0.4) 10) Power Supply & Voltage: 85-240VAC,180-275VAC,50/ 60Hz,24VAC/DC,50/60Hz 11) Range of voltage: 85-275VAC,165-380VAC,22-26VAC/DC 12)Ambient Temperature:-5~50 13)Ambient Humidity: 80%RH 14) Weight: 230g 15)Power Loss: 4W 16) Insulation resistance: ≥10meg-ohm(testing condition 500V) |
|
|