Automatic air-conditoner parts temperature controller MT02 for 100% guaranteed quality
1.Best design.
2.Best service
Automatic air-conditoner parts temperature controller MT02 for 100% guaranteed quality
Technical parameter:
Power voltage:AC24,110V,230V(220V),50HZ-60HZ.
Load current:<3A
Temperature-sensitive component:gas-filled diaphragm.
Environment temperature:-5-50degree.
Temperature differential:<=1degree (in 25 degree)
Shell protection:IP20 shell material:anti-flame ABS/PC.
Temperature-setting driver plate,the pointer means the required constant temperature.
System starter,ON/OFF means to connection/disconnection respectively for the power of thermostat.
Low-Medium-high(If it is fan valve controller,this function is not available)
Mechanical transmitting component with reliable structure can satisfy the requirment of being used in more harsh environment.
Item No. | Rated voltage | Load current | Range | Differential | N.W(kg) |
MT02A/MT02AF
| 230V±10%AC 110V±10%AC 24V±10%DC | ≤3A | 10°C~30°Ccan be customized 5°C~35°C | ±1°C(25°C) | 183 |
10°C~30°C | 190 | ||||
8°C~30°C | 180 | ||||
MT02D/MT02DF |
Model | Controlled object | Explaination | Applicable system | ||||||
MT02AE | Two-wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
valve and three | value,the motorized value is closed,the fan will | water system | |||||||
speed FCU | operate according to the selected speed | ||||||||
MT02AE1 | Two-wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
valve and three | value,the motorized value is closed | water system | |||||||
speed FCU | |||||||||
MT02BE | 3 wire motorized | When environment temperature reach to setting | Four-tube standard | ||||||
vale,motorized ball value | value,the motorized valve is closed,the fan will operate according to the selected speed | water system | |||||||
and 3 speed FCU | |||||||||
MT02AS | 3 wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
vale,motorized ball value | value,the motorized value is closed,the fan will | water system | |||||||
and 3 speed FCU | operate according to the selected speed | ||||||||
MT02AS1 | 3 wire motorized | When environment temperature reach to setting | Four-tube standard | ||||||
vale,motorized ball value | value,the motorized value is closed,the fan will | water system | |||||||
and 3 speed FCU | operate according to the selected speed | ||||||||
MT02BS | Two-wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
valve and three | value,the motorized value is closed,the fan will | water system | |||||||
speed FCU | operate according to the selected speed | ||||||||
MT02AE2 | 3 wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
vale,motorized ball value | value,the motorized value is closed,the fan will | water system | |||||||
and 3 speed FCU | operate according to the selected speed | ||||||||
MT02AS2 | Fan mouth of motor of | According to the difference between in-house temperature and | |||||||
motorized fan valve | setting temperature,closing or opening motorized fan valve is | Fan system | |||||||
controlled by the thermostat automatically | |||||||||
MT02F | Two-wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
valve and three | value,the motorized value is closed,the fan will | water system | |||||||
speed FCU | operate according to the selected speed |