Welcome to B2BAGE
YD-1 Smart Vibration Calibrator
YD-1 Smart Vibration Calibrator

Minimum Order: 0
Quality/Safety Certification: 0.00


YD-1 Smart Vibration Calibrator
1. Origin: China
2. Model: YD-1
3. Output Current: 4-20mA

YD-1 Smart Vibration Calibrator

 

Description of the Panel 

 YD-1 type vibration transducer calibration panel layout as shown:

 

1. Liquid crystal display window

  Specific content please see the note behind.

2. Power switch

   220V AC power switch.

3. 220V AC power input socket

  Connect 220V AC power supply

4. transducer fixed platform

  Fix the calibrated transducer

5. RS232 interface

  PC connects to the interface by USB turn to serial cable, then the PC can control the vibrating table.

6. The calibrated transducer signal input socket

  The signal( voltage signal ) that output by the calibrated transducer connects to the socket, the vibrating table can measure and display it.

7. The calibrated signal input socket

  The input calibrated transducer signal output from the socket, so as to use the digital universal standard or other apparatus for measurement. 

8. 24V voltage output binding post

   provide -24V power for the proximitor when calibrate the eddy current transducer. 

9. 4 ~ 20mA current input positive binding post

10. 4 ~ 20mA current input negative binding post

 

Operation buttons

Eddy current transducer bracket fix the screw

When calibrate the eddy current transducer, fix the fixing bracket on the control panel through the screw holes.

 

Main technical index: 

1. Parameters for YD-1 type vibration transducer calibration table:

      Acceleration(m/S2)    peak value

     Speed ( mm / S )         effective value

     Displacement ( μm )      peak-peak value

2. Power: 220VAC±10%, with fuse, can operate more than an hour continuously.

3. Maximum load weight: ≤1000g

4. Vibration frequency range: 10~1280Hz; resolution: 1Hz.

5. Vibration amplitude setting range

  Acceleration(m/S2): ≤50.00 ( resolution is 0.01G, accuracy is 3‰ )

  Speed ( mm / S ):  ≤100.00 

  Displacement (μm ): ≤2000

6. The output vibration signal error: ≤±0.3dB±1 words

  Frequency accuracy: < 0.05Hz

7. The maximum vibration amplitude and maximum load value

Due to the vibrating table for YD-1 type vibration transducer calibration instrument is small, the output amplitudes by the calibration instrument are different when different transducers are calibrated in different frequencies. The maximum vibration amplitude value and maximum load value is defined as under a certain frequency, the maximum acceleration, speed or displacement value that output by the calibration instrument when the calibrated transducer is in a weight. Please refer to the following table for the specific indicators ( frequency sample value: 10,20,40,80,160,320,640,1280Hz ).

Weight 

Frequency

≤100g

≤250g

≤500g

a(m/S2)

v(mm/S)

d(μm)

a(m/S2)

v(mm/S)

d(μm)

a(m/S2)

v(mm/S)

d(μm)

10Hz

2.5

25

2000

2.5

25

1500

2

25

1000

20Hz

10

50

1800

10

50

1200

6

50

700

40Hz

40

100

1500

40

100

1000

20

60

400

80Hz

50

100

400

50

80

300

20

40

200

160Hz

50

50

100

50

50

80

20

20

60

320Hz

50

20

25

40

20

20

15

10

10

640Hz

30

10

3

20

5

5

10

3

*

1280Hz

25

3

*

10

2

*

3

0.4

*

 

* in high frequency, the vibration displacement is very small, so, in this point, there is no vibration signal output from the calibration table.