35KV two winding off circuit tap changer distribution transformer
35KV two winding off circuit tap changer distribution transformer

Minimum Order: 0
Quality/Safety Certification: 0.00


35KV distribution transformer:
a.loss reduction
b.strong withstanding short circuit ability
c.enviromen proection

35KV two winding off circuit tap changer distribution transformer:

Rated Capacity (kVA)Voltage Combination Connection SymbolNo-load loss(KW)load loss(kw)No-load Current(%)short Circuit Impendence (%)Center Distance (mm)
H.V (kv)Tapping Ranger of H.Vl.v (kv)
5035±5%0.4Yyn00.181.161.46.5660
1000.251.931.26660
1600.322.691.16660
2000.393.161.09660
2500.453.760.98660
3150.534.530.98660
4000.645.470.91820
5000.756.580.91820
6300.917.860.88820
8001.089.410.74820
10001.2611.540.7820
12501.5413.940.61070
16001.8616.670.531070

The series of oil-immersed transformer such as S9(10), SF9(10), SZ9(10),  SFZ9(10) has a voltage of 35kV and a capacity of 50-50000kVA.

This series of products are a new generation products that can remarkably save materials and reduce losses. It is designed on the basis of digesting and absorbing the advanced technology at home and abroad, having hightech content and stronger competitive power. The product SZ1120000/35 new designed have passed the assessment of scientific and technical results by the scientific and technological bureau of Shandong Province.

The product possesses the following characteristics:

1) Adopting the electromagnetic calculation procedure of the computer, to optimize the plan of design; By comparing and analyzing the technical parameter and technical and economic index, to confirm the best plan of design.

2) The core adopt the new technology of threegrade and going forward one by one overlapping:

The core is high quality coldroll crystallite orientation silicon steel plate which import from Japan. Its section cut straight through is multistage round, miter jointing. Adopting the new technology of two pieces threegrade and going forward one by one overlapping. The new technologys practice cause noload loss average lower 810. It save energy remarkably.

3)  The main and vertical insulation of the body of Transformer is on the basic of electric field calculation and model testing, and integrate the successful experience and renew definite. It increase the ability to resist short circuit effectively.