Dry Type Insulated Current Transformers
Dry Type Insulated Current Transformers

Minimum Order: 0
Quality/Safety Certification: 0.00


Electronic Current Transformers
1.Max Voltage:252KV
2.Rated Primary Current:300 to 4000A
3.Rated Secondary Current 5A
4.GOST

Electronic Current Transformers
1.Max Voltage:252KV
2.Rated Primary Current:300 to 4000A
3.Rated Secondary Current 5A
4.GOST 

LVQB(T)-35/66/110/220 type SF6 gas insulated current transformer
Altitudenot exceed 2000m(the ones exceed 2000m shall be designed separately)
Ambient temperature-40°C~+50°C, daily mean temperature not exceeds 30°C
Max monthly mean relative humidity90%
10min max average wind velocity35m/s
Max ice coating thickness10mm
Class of pollution3 4 Class
Max voltage of equipment40.5/72.5/126/252kV
Rated frequency50Hz
Rated primary current300~4000A
Rated secondary current1A or 5A
Secondary combination0.2, 0.2S, 0.5, 0.5S, 5P, TPY, TPS Class combination at random
Rated output0.2 class, 0.2S class, 0.5class, 0.5S class, 5P class: 20~60VA TPY class:10~20Ω
Accuracy limit condition of class TPYa. primary time constant Tp=100ms or 60ms
b. short-circuit current direct component 100%(i.e. full migration)
c. specified working cycle: C-0.1s-0-0.5s(or 0.4s)-C-0.1s-0(guarantee all accuracy class times are 0.4s)
d. symmetrical short-circuit current multiple: 10, 15, 20
Rated insulating levelcurrent transformer of 35kV: 40.5/95/185kV; Current transformer of 66kV: 72.5/140/325kV; Current transformer of 110kV: 126/200/480kV; Current transformer of 220kV: 252/395/950kV                
Short-time thermal current50-63kA, 3S
Rated peak withstand current125-160kA(peak)
Withstand voltage level under zero gauge pressure1.3 times of max working voltage of equipment
Partial discharge level1.2 times of max working voltage of equipment ≤5pC
Annual gas leakage rate≤0.5%
Water content of SF6 gas≤150×10-6(V/V)
Specific creepage distace of external insulation25mm/kV or 31mm/Kv
Static bearing load of primary terminal2000N~6000N
Max total mass of productcurrent transformer of 35kV: 450kg(thereinto mass of SF6 gas is 4kg); current transformer of 66kV: 500kg(thereinto mass of SF6 gas is 5kg); current transformer of 110kV: 450kg(thereinto mass of SF6 gas is 7kg); current transformer of 220kV: 1400kg(thereinto mass of SF6 gas is 23kg); 

 

 