1. Double-channels Syringe pump
2. Double CPU
3. Body weight mode, Time mode, Rate mode and link mode
4. Good quality

Maximum injection rate

1500 ml/h (Different syringes have different maximum flow rate.)

Injection flow rate range

5 ml injector: 0.1~100ml/h

10 ml injector: 0.1~200 ml/h

20 ml injector: 0.1~400 ml/h

30 ml injector: 0.1~600 ml/h

50 ml injector: 0.1~1500 ml/h

Injection increment

0.1

Bolus rate

5 ml injector: 100ml/h

10 ml injector: 200 ml/h

20 ml injector: 400 ml/h

30 ml injector: adjustable from 400~600 ml/h

50 ml injector: adjustable from 400~1500 ml/h

Injection mode selection

1. Rate mode; 2. Time mode; 3. Body Weight mode; 4. Link mode

Rate mode

Rate: 0.1~1500.0ml/h (maximum value depends on the injector specifications)

Time mode

Time: 1minute~2000 minutes  Volume limit: 0.1ml~999.9 ml

Body Weight mode

Weight: 0.1~300.0 kg

Drug: 0.1~999.9 mg

Volume: 0.1~999.9 ml

Dose: 0.1~9999.9 (restricted to unit, drug, solution, weight and injector specification).

Unit: mg/kg/h, ug/kg/min

KVO rate

Adjustable range: 0~5.0ml/h (begin the KVO function under the occlusion situation); Setting value as 0 to cancel the KVO function when it is unnecessary in use.

Water-proof grade

IPX1

Injection pressure

The maximum pressure is 300 kpa, occlusion alarm pressure gate value is 40kPa~160kPa, when pressure value is minimum, injection rate is 5ml/h, the longest alarm time is 10 minutes.

Preset volume scope

0.1~999.9 ml

Preset time scope

0~2000 minutes

Accumulated injection volume display

0.1~999.9 ml

Injection accuracy

±5%

Power supply

100V-240V~, 50Hz±1Hz, 30VA

Battery

Rechargeable lithium polymer battery, 7.4V, 1600mAh

Maximum power consumption

10VA, running more than 2 hours at the rate of 5ml/h after being fully charged.

Battery charge

When double-channel syringe pump is connected to AC power and the power is on, the battery will charge automatically. (about 8~14 hours to recharge fully)

Fuses

T 2AL 250V~

Displayed and indicated information

Injection rate, accumulated volume, syringe specification, battery capacity, bed No., AC power indicator, operation indication, etc.

State indication information

Stop, injection, bolus, KVO ( If KVO rate is set as 0, it doesn’t display KVO when occlusion alarm occurs)

Alarm functions

Near completion, Over, occlusion, disengage, low battery, abnormal 1, abnormal 2, abnormal 3, abnormal 4, serious low battery

Size of the outer shell

320 mm×110 mm×200mm  (length×width×height)

Net weight (excluding power cord)

3.4 kg

Classification

ClassII, Type BF

Outer shell material

ABS Plastic

Operating condition

Environment temperature:+5°C~+40°C, air pressure: (86~106)kPa, relative humidity: ≤80%

Storage condition

Environment temperature:-40°C~+55°C, air pressure: (50~106)kPa, relative humidity: ≤95%. No poisonous gas and well ventilation

Applicable syringes

National standard syringes: 5ml, 10 ml, 20 ml, 30ml, 50 ml

Standards

GB9706.1-2007, GB 9706.27-2005, ISO7886-1:1993, GB9969.1-1998,

GB/T14710-1993, GB191-2008, YY0466-2003