Welcome to B2BAGE
TWELVE CHANNEL ECG
TWELVE  CHANNEL ECG

Minimum Order: 0
Quality/Safety Certification: 0.00


TWELVE CHANNELECG Twelve Channel digital ECG machine with Interpretive.

TWELVE  CHANNEL ECG  

Functions

1.         Twelve Channel digital ECG machine with Interpretive.

2.         Simultaneous 12 lead acquisition, 12-channel, 6-channel printing form at     choice. Date, time and parameters, including paper speed, heart rate, sensitivity, filter status, and etc. print out.

3.         Designed with a high-resolution thermal printer to print out ECG waveform, annotation as well as related parameters for diagnosis reference.

4.         Recording paper for ECG-912A is 210mm in width.

5.         Simultaneous 12 lead acquisition.

6.         Visual display of operation menu, ECG waveform and parameters.

7.         Digital isolation technology is adopted to minimize time/temperature drift of components so as to promote adaptability of the unit to circumstance.

8.         Digital filter for effective inhibition of baseline drift, interference, as well as automatic position of baseline.

9.         Self-test upon powering on.

10.     Function of rhythm lead for observing abnormal ECG waveform & heart rate.

11.     Automatic measurement and interpretation of ECG waveform to relieve doctors from strain.

12.     Multiple print formats include 6-channe and 12-channel.

13.     AC/Rechargeable battery for continuous examination when AC power supply is unavailable. For battery operation, ECG-912 is equipped with a charger & system for battery capacity management and protection itself from excessive discharge.    

14.     Safety level for ECG-912A corresponds to Class I, type CF.

15.     Quanlity assurances: ISO13485

Specifications:

Lead

Standard 12 leads

Input Circuit

Isolated input circuit

Protection against defibrillation and pace making

Data Acquisition

Simultaneously 12 lead acquisition

Calibration Voltage

1mV±5%

Sampling Rate

1ms

A/D Converter

12 bit

Print Format

Automatic/Manual: 6 channel, 12 channel

Neutral value + Rhythm lead

Operation Mode

AUTO: Automatic lead change;

Automatic measurement and interpretation

MAN: Manual lead change

Parameter Measurement

Ventricle heart rate; P-R interval; QRS duration;

QT/QTC interval; P/QRS/T axis; RV5/SV1 amplitude

Filter

AC filter, EMG filter, DFT filter

CMRR

> 60dB

> 100dB (AC filter in use)

Input Circuit Current

≤0.1mA

Input Impedance

>50MW

Patient Leakage Current

<10mA

Time Constant

≥3.2s

Frequency Response

0.05 ~ 100Hz

Noise Level

<15mVp-p

Threshold

≤20mV

Skin Voltage Tolerance

±300mV

Sensitivity

5, 10, 20mm/mV

Baseline Control

Dimensions of Packing 

Automatic baseline control

Automatic inhibition of baseline drift

Dimensions

400mm*325mm*84.5mm

Dimension of Packing

510mm*430mm*230mm

N.W

6kg

G.W

8kg

 

 

Environment Conditions

Transportation

Storage

Operation

Temperature:

-40∼+55

-10∼+40

+5∼+40

Relative Humidity:

25%∼95%Non condensed

25%∼80%

25%∼80%

Atmospheric Pressure:

700hPa∼1060hPa

700hPa∼1060hPa

860hPa∼1060hPa

Accessories:                 

1.Patient cable1 PC
2.Limb electrode4 PCS
3.50mm X 20m roll ECG paper1 Roll
4.Three plugged power cable1 PC
5.Chest electrode..6 PCS
6.Backup AC fuse2 PCS
7.Operating instructions1 Copy
8.Earth connecting line.1 PC
9.Certificate.1 Copy

 

 

 

       

 