1.Online protection
2.Motorola Microprocessor
3.Advanced Current Control
4.IGBT power compone
5.ups manufacturer
Outstanding Feature
1. Texas Instruments DSP processor
2. Motorola Microprocessor
3. Module design
4. Advanced Current Control
5. IGBT power component
6. Power Factor Correction
7. Online Maintenance
8. High frequency and double conversion on-line technology
9. Advanced PFC technology
10. EPO Function
11. Wide input voltage range
12. Fully digitized microprocessor control
13. Parallel redundancy
14. Advanced battery management
15. Lightning and surge protection, short circuit and overload protection
16. Multilingual LCD display
Technical specification
MODEL | C6K(S)L | C10K(S)L | 3C10KSL | 3C15KSL | 3C20KSL |
Power(VA/Watt) | 6000VA/4200W | 10000VA/7000W | 10000VA/7000W | 15000VA/10500W | 20000VA/14000W |
INPUT | |||||
Voltage & Voltage Range | 220 VAC, 1 Phase + Neutral | 220 VAC, 1 Phase + Neutral | 380 VAC, 3 Phase + Neutral | 380 VAC, 3 Phase + Neutral | 380 VAC, 3 Phase + Neutral |
Voltage Tolerance | 176 – 276 VAC ± 3% | 176 – 276 VAC ± 3% | 304 – 478 VAC ± 3% | 304 – 478 VAC ± 3% | 304 – 478 VAC ± 3% |
Power Factor | ≥ 0.98 | ≥ 0.98 | ≥ 0.95 | ≥ 0.95 | ≥ 0.95 |
Current (nominal) | 23 Ampere | 37 Ampere | 13 Ampere / Phase - 39 A | 23 Ampere / Phase - 69 A | 30.3 Ampere / Phase - 91 A |
Input Fuse | 32 A NFB | 50 A NFB | 63 A NFB | 100 A NFB | 100 A NFB |
Frequency & Frequency Range | 50 Hz, 46 ~ 54 Hz | ||||
Working with Gen Set | Perfect Voltage and frequency Compatibility | ||||
OUTPUT - INVERTER and BYPASS | |||||
Load Power Factor Range | 0.65 inductive - 1.0 resistive | ||||
Voltage Wave Form | Sinusoidal | ||||
Voltage & Voltage Tolerance | 220 / 230 / 240 VAC ± 1% | ||||
Dynamic Response | At 50% - 100 - 50% unbalanced load, max voltage decline < ± 5% | ||||
Recovery Time | At Dynamic load Changes, Output Voltage recovery time is 60 msec ± 1% | ||||
Total Harmonic Distortion | For Linear Load ≤ 2%, Non Linear Load ≤ 6% | ||||
Frequency & Frequency Range | 50 Hz / Mains 46-54 Hz, Battery Mode ± 0.1% (0.05 Hz) | ||||
Crest Factor | 3:1 | ||||
Over Load (Mains) | For 105% - 130% load 10 mins., for > 130% load transfer to bypass after 1 sec, shutdown after 1 min at overloaded bypass | ||||
Over Load (Battery) | At > 105% load shut down after 10 sec. | ||||
Bypass and Transfer Time | Standard static bypass, Completely Uninterrupted transfer between Mains - Battery / Battery - Mains | ||||
Bypass Voltage Tolerance | 176 – 261 VAC, 1 Phase + Neutral | ||||
BATTERY | |||||
Type and Placement | Maintenance Free, Dry Type | ||||
Nominal Battery Voltage | 240 VDC | ||||
INDICATORS & CONTROL PANEL | |||||
Type | LCD Panel | ||||
Control Panel | Push Buttons (Open / Close, Audible Alarm Cancellation) | ||||
Measuring and Alarms | % Load, Input Voltage Exist, Output Voltage Exist, Bypass Active, Battery Mode, Battery Capacity (%), Inverter in Service, Fault | ||||
Indicators (LED) | Mains On, Mains Reverse, Battery Mode, Bypass On, Load / Battery Level, Overload, Fault | ||||
PROTECTIONS | |||||
Overload | Electronic Protection is available. In case of exceeding limits, the load is transferred to bypass without any interruption | ||||
Short Circuit | Inverter shuts down automatically | ||||
Over Temperature | If the internal Temperature is 90°C the load is transferred to bypass, When it returns < 80°C, Inverter starts to work | ||||
Modem / Network Protection | Modem / Network protection input against to Voltage Spikes | ||||
AUDIBLE ALARMS | |||||
Alarm Type and Alarms | Buzzer, it can be switched off by audible alarm button. | ||||
Battery Mode, Battery Low, UPS fault, Overload, Short Circuit, Over Charge, Charger, Bypass, Inverter fault, Communication fault | |||||
COMMUNICATION | |||||
Interface and Protocol | Standart DB 9 (Female) Port, Intelligent RS232 (standard), SNMP(optional) and DB25 parallel port (for paralelling, optional) | ||||
Software | Winpower-XP | ||||
GENERAL | |||||
Total Efficiency At 100% load | 88% | ||||
Noise Level | ≤ 55 dBA | ≤ 60 dBA | |||
Electro Magnetic Compatibility | EN 61000-4-2 (ESD), 4-3 (RS), 4-4 (EFT), 4-5 (surge), IEC 62040-2 (EMI) | ||||
Operation Temperature and Humidity | 0 °C ~ 40 °C, maximum 20-90% (Non Condence) | ||||
Storage Temperature | -20 °C ~ +70 °C | ||||
Protection Class | IP20 | ||||
Cooling Type | Forced cooling with variable speed fan according to load % | ||||
Operation Altitude | ≤ 1000 meter (from the sea level), at nominal load | ||||
Dimensions (mm), W x H x D | 260x717x570 | ||||
Weight W/O / W/Battery (kg) | 35 / 84 | 38 / 93 | 38.5 | 55 | 55 |