GC9790II Gas Chromatography
1.Capillary and packed column inlets,
2.split and splitless, cool-on-column

GC9790II Gas Chromatography

 

Capillary and packed column inlets, split and splitless, cool-on-column

Programmable oven, 8 ramps temperature programming, 6 temperatures, up to 400º C

Wide dynamic range of popular detectors: FID, TCD, NPD, ECD and FPD

Instrument control, method setup and run from keyboard entries

 

Rugged manual injection and manual pneumatics

Self-diagnosis of controls: Thermal zone, flows, and detectors

Ready to use when product delivered and installed

Unbeatable price and service package

 

Guarantee timely and no-hassle service responding

Dual pneumatics

 

Dual packed column inlets
GC9790IIFDual FID Detector
GC9790IITTCD Detector
GC979IIT-2TCD Detector (new type)
GC9790IIPFPD Detector
GC9790IIE

ECD Detector

 

GC9790IIGDual FID Detector, dual amplified board
GC9790IIBDual FID Detector, TCD Detector
GC9790IIB-2Dual FID Detector, TCD Detector (new type)
GC9790IIDFID Detector, FPD Detector
GC9790IIK

Dual FID Detector, ECD Detector

 

GC9790IIHTCD Detector, FPD Detector
GC9790IIL-3Dual FID Detector, ECD Detector, FPD Detector

Packed column inlet, Capillary column inlet (split and splitless)

 

GC9790IIJDual FID Detector
GC9790IIRFID Detector, NPD Detector
GC9790IICDual FID Detector, dual FID amplified board
GC9790IIA

Dual FID Detector, TCD Detector

 

GC9790IIA-2Dual FID Detector, TCD Detector (new type)
GC9790IIIFID Detector, FPD Detector
GC9790IIL

Dual FID Detector, ECD Detector

 

GC9790IIL-2FID Detector, ECD Detector, FPD Detector
GC9790IIL-4FID Detector, ECD Detector, NPD Detector
GC9790IIL-5

FID Detector, NPD Detector

 

GC9790IIL-6FID Detector, ECD Detector, NPD Detector
Dual Capillary column inlets (split and splitless)
GC9790IIQDual FID Detector
GC9790IINDual FID Detector, dual amplified board

 

Detector: FID

 

Detection limit≤3x10 -12 g/s
Sensitivity Mv.ml/mg[n-C16] 
Noise≤3x10 -14 A
Drift≤5x10 -13 A/30min
Linear range≥10 6

 

Detector: TCD

 

Detection limit 
Sensitivity Mv.ml/mg[n-C16]≥2500
Noise≤20μV
Drift≤100μV/30min
Linear range≥10 4

 

Detector: TCD(new type)

 

Detection limit 
Sensitivity Mv.ml/mg[n-C16]≥8000
Noise≤20μV
Drift≤100μV/30min
Linear range≥10 4

 

Detector: ECD

Detection limit≤1x10 -13 g/ml
Sensitivity Mv.ml/mg[n-C16] 
Noise≤20μV/30min
Drift≤50μV/30min
Linear range≥10 4

 

Detector: FPD

Detection limitMt≤1.4x10 -12 g/s(P), Mt≤5x10 -11 g/s(S) methyl parathion
Sensitivity Mv.ml/mg[n-C16] 
Noise≤4x10 -10 A
Drift≤4x10 -10 A/30min
Linear range≥10 3 (P), ≥10 2 (S)

 

Detector: NPD

Detection limit 
Sensitivity Mv.ml/mg[n-C16]Mt≤5x10 -13 g/s(N) Malathion, Mt≤1x10 -12 g/s(P) azobenzol
Noise≤4x10 -13 A/30min
Drift≤2x10 -12 A/30min
Linear range≥10 3