Welcome to B2BAGE
laboratory EDI pure water machine 05L/10L/15L/20L/30L
laboratory EDI pure water machine 05L/10L/15L/20L/30L

Minimum Order: 0
Quality/Safety Certification: 0.00


EDI (Electro-deionization) is the most advanced technology of water treating in current international, using RO and EDI

EDI series ultrapure water machine (FLOM-E series)

ENVIRONMENTAL PROTECTION AND TECHNOLOGY

More reliable water quality

EDI (Electro-deionization) is the most advanced technology of water treating in current international, using RO and EDI integrated process, It operates steadily, produces high-quality water, is designed modularly, need no acid-base reclaim, can reduce food-print and consumption, also reduce the costs of operating maintenance. It turns from traditional water treating technology to“Green Environmental protection, Technological innovation”

Characteristics and Advantages of EDI system

The system can operate automatically, needs no chemical reclaim, saving acid and base; in order to prevent stem and pollution to reduce its operating life, EDI have certain requirements for inlet water quality, usually taking RO Permeable water as the inlet water. Proper anti-permeable RO water enters into EDI system via booster pump, the mixed ion exchange resin membrane stack of EDI will continuously exchange the anion, cation of water, however ionize the hydrone beside the anion membrane and cation membrane through electric current of membrane stack, to make it produce H+ and OH-, ionized H+ and OH- will reclaim mixed ion-exchange resin, meanwhile replaced anions,cation of formal water separately pass anion membrane and cation membrane to enter into concentrating compartment, part of concentrated water flows back to keep conductivity of concentrated water, and other part of concentrated water and electrlyte will goes into trench. The reclaiming progress of Electronics makes EDI system produce deionized water while no need to stop and no need traditional reclaiming equipment.

The equipment can take place of traditional ion exchange(DI), to produce ultrapure water, and the conductivity can reach to10-18.25MΩ.cm

Applicable fileds:

FBZ-E:

used for making buffer solution\analysis and test of atomic absorption(AA)\atomic fluorescence(AFS)\ High Performance Liquid Chromatography(HPLC)\mass spectral analysis(MC)\Inductively Coupled Plasma (ICP),etc

FCR-E:                 

amino acid analysis\ protein purification\ electrophoresis/ gelatin analysis\ animal and plant life cell culture\ Items of molecular biology experiment\ electrophoresis\ molecular biology experiment\ PCR.

FDY-E:

chromatography of ions\ trace metal analysis\AES\ buffer solution\ High-purity standard solutions/ quantitative analysis of microelement\ HPLC highly active liquidoid chromatogram; toxicity\ race mineral analysis\ HPLC\ TOC analysis/ IC\IC/MS analysis

FJY-E:

DNA/RNA preparation; DNA sequencing; HPLC(amino acid \penicillin analysis\organic component measuring); protein purification\ protein analysis\; toxicity test; TOC test; IVF,CR ,Cell culture,capillary electrophoresis\ molecular biology experiment and immunity.

Technical Parameters

Product Name

FBZ-E

FCR-E

FDY-E

FJY-E

Product model

FBZ(05-30)01/02

FBZ(40-100)01/02

FCR(05-30)01/02

FCR(40-100)01/02

FDY(05-30)01/02

FDY(40-100)01/02

FJY(05-30)01/02

FJY(40-100)01/02

Working condition

Raw water: municipal tap water

Raw water TDS:≤200PPm

Inlet water Pressure:1-5kg/cm2

Wter Temperature: 4-40°C

Conductivity

0.055µs/cm

0.055µs/cm

0.055µs/cm

0.055µs/cm

Resistivity

18.25MΩcm

18.25MΩcm

18.25MΩcm

18.25MΩcm

TOC

TOC≤20PPb

TOC≤10 PPb

TOC≤1-5 PPb

TOC≤2-5 PPb

Intercepting rate of pollutants(%)

≥99

≥99

≥99

≥99

Particulate (size>0.22µm)

<1(granule)/ml

<1(granule)/ml

<1 (granule)/ml

<1 (granule)/ml

Bacteria

<1cfu/ml

<1cfu/ml

<1cfu/ml

<1cfu/ml

Endotoxins 

<0.01EU/ml

<0.01EU/ml

<0.01EU/ml

<0.01EU/ml

R Nase

<0.003ng/ml

<0.003ng/ml

<0.003ng/ml

<0.003ng/ml

Water flow rate

1-2.0L/min

1-2.0L/min

1-2.0L/min

1-2.0L/min

Water output

5-100L

5-100L

5-100L

5-100L

Measurement

430*501*530mm(5-30L); 600*580*1030mm(40-100L)

Weight

30KG(5-20L);50-100KG(40-100L)

Remarks

1.All data above are the technical parameters of Flom single stage reverse osmosis ultrapure water machine-FCR/FDY/FJY(01); if users’ feed water TDS values> 200PPm or need more water, Flom two stage reverse osmosis ultrapure water machine- FCR/FDY/FJY(02)will be a good choice.

2.If user has pure water or distilled water whose conductivity <10μs/cm, they can use FCR / FDY / FJY entering distilled water type ultrapure water machine, Its water production can reach 20-90 L/h, producing water quality parameters are the same with the ones in table above

 

  

  