Welcome to B2BAGE
SRUF-250 MEMBRANE MODULE ,HOLLOW FIBER UF MEMBRANE FOR WATER TREATMENT
SRUF-250 MEMBRANE MODULE ,HOLLOW FIBER UF MEMBRANE FOR WATER TREATMENT

Minimum Order: 0
Quality/Safety Certification: 0.00


-Membrane module SRUF-250
-UF technology is efficient,environmentally,energy-saving separtation process
-Water flux is large

Hollow-fiber Ultrafiltration Membrane Module SRUF-250 

The characteristics of Ultrafiltration technology:

-UF tech. is an efficient and environmentally,energy-saving separation process

-Using lower pressure as a driving force

-UF separation process is on under room temperature,low energy consumption

-The scale and handle ability range of UF process is large

 

More info. pls visit to our website: www.suoai.en.alibaba.com

Any question pls feel free to contact us(Trade Manager is cn220180523)

 

1.PERFORMANCE PARAMETERS

Membrane materialPolyvinyl Chloride(PVC)Molecular Weight Cut-off(MWCO)80.000-10.000 Dalton
Inner and outer diameters of hollow-fiber0.9mm/1.6mmMembrane fiber typeInside-out hollow-fiber
Charateristics of membrane structureHydrophilic double-compact layers  
    

2.APPLICATION CONDITIONS

Pre-filtration50-150umMax. turbidity of inlet water<=15NTU Rate flux60-160L/M/H 
Running modeCross-flow filtration or dead end filtration  Max.inlet water pressure0.45MPa 

Pressure difference of transmembrane at 20°c(TMP)

 28-150KPa
Max.Pressure difference of transmembrane 

 0.2MPa

 

 Applicable PH range 2-12 Applicable temperature 5°c
 Tolerable continuous residual chlorine 100PPm   Tolerable interval residual chlorine 200PPm

3.BACKWASHING DESIGN

Backwashing pressure0.25MPaBackwashing flow220-300L/M/HBackwashing frequencyEvery20-60 minutes
Backwashing time30-60 seconds every timeFrequency of chemically enhanced backwashing(CEB)Auto adding of additives in backwashing is recommendedTime of chemically enhanced backwashing(CEB)30-60seconds every time

4.CHEMICALLY WASHING DESIGN

Frequency of chemically washingevery1-4months or when TMP is over0.15MPaPressure of chemically washing0.15MpaFlow of chemically washing200-250L/M/H
Time of chemically washing60-90 minutees every timeAcid washing chemicalCitric acid or oxalic acid(mixed into solution with PH=2) Alkali washing chemicalNaoH (mixed into solution with PH=2)

 5.INDEX OF OUTPUT WATER

Turbidity of output water<0.1NTUIndex of silt density<1.5
Remarks:

1.Pure water flux is measured with pure water at25°c with inlet water pressure of 0.1MPa.

2.If water sources are from surface water,river water or well water and so on,pre-treatment shall be done.

It is suggested that a 50-150um precision filter shall be equipped to have inlet water with turbidity<=15NTU.

 Microorganism,pathogen99.9%Removed 

 

 

 

 

Ads by Google