welding cable
1 it is approved by ISO,CCC,CB,CE,RoHS
2 jacket:PVC,rubber for option
3 conductor:copper,CCA for option
welding cable
1 also named welding cable/rubber welding cable/electrical welding cable/welding machine cable
2 Welder apply to the secondary side wiring and connecting welding clamp dedicated cables, the exchange does not exceed the rated voltage 200 V DC and pulse of 400 V peak.
3 Single core structure, a multi-unit complex cutter made of soft wire. Conductive wire core heat-resistant polyester film used outside insulation wrap packages, with the outermost layer of insulation made of rubber sheathing as a protective layer.
Instruction
Cables are suitable for the secondary side voltage exchange does not exceed 200 V and 400 V peak pulsating DC welding machine with secondary side wiring and connecting welding clamp purposes. Cable allows long-term temperature: ≤ +65
Type:
Type | Name |
YH | Welder natural rubber sheathing cables |
YHF | Chloroprene or elastomer sheathe cable welder |
Cable main technical performance
section | Core structure cores/mm | 20 conductive wire core DC resistance Ω/km | |
No Tinning | Tinning | ||
10 | 322/0.20 | ≤1.19 | ≤1.95 |
16 | 513/0.20 | ≤1.16 | ≤1.19 |
25 | 798/0.20 | ≤0.758 | ≤0.780 |
35 | 1121/0.20 | ≤0.536 | ≤0.552 |
50 | 1596/0.20 | ≤0.346 | ≤0.390 |
70 | 2214/0.20 | ≤0.268 | ≤0.276 |
95 | 2997/0.20 | ≤0.198 | ≤0.204 |
120 | 3702/.0.20 | ≤0.161 | ≤0.164 |
Note: Finished drills immersion in water 1 hour at room temperature, withstood 50Hz, 200V AC voltage of 5 min no breakdown.