... 8. Hush feature to silence nuisance alarms 9. Low battery alarm 10. Test button 11. Relay contacts-volt free with Normally ... rated to 24 volts /1amp resistive 13. High sensitivity 14. Alarm supplied with "connector plug" for ease of installation 15. CE ...
good-looking, easy to assemble, iron box with lock. compatible for all brand. 1. 4 wired zones ,10 wirelesss zones. 2. 4 groups telephone, each group can achieve 15 digits. 3. Contact ID, LX6688 communication protocol. 4. AC/DC power auto switch.
... 10 zones light,supports 30detector 4 auto dial alarm.monitor location 1.how to use install a ... sensor for door ,a wired door sensor for strobe, a smoker sensor for kitchen, and use a ... the thief come into hall ,door windows or fire in the kitchen ,will alarming with remote control2. ... -dial 8phone No. while alarming.4.automatically dial alarm. Alarm monitoring the location of the sound field.5.could ...
Fire Air Respirator RHZK Self-contained positive pressure air breathing apparatus for Fire-fighting Fire Air Respirator Model Working pressure(Mpa) Volume Air Deposit(L) Using Term(min) Alarm Pressure(Mpa) Weight(Kg) Packing(mm)RHZK5/30305150040~504~6≤12755*460*290RHZK6/30306180050~604~6≤12755*460*290RHZKF6.8/30306.8204050~604~6≤12755*460*290
... CO2 8522 series single point wall-mounted CO2 detective alarm is an apparatus which can continuously detect CH2O ... and RS485 digital signal output.ApplicationPetroleum and petrochemical industry, Fire rescue,various types of industrial safety monitoring, detection of ... parameter:Product name Single point wall-mounted CO2 detective alarm Sensor name CO2 infrared moduleProduct model SV-CO2 8522 ...
... 32automatic arm / disarm disarm w SFL-8016 Bus Intelligent Alarm System Function & Features:Adopted embedded system design, 32- ... electronic map, DVR alarm input, alarm and other functions.Perimeter prevention, emergency assistance, hotel services, fire and other application mode ... central computer to arm/disarm.Via telephone lines and alarm center through the contact ID protocol connection, the user ...
... exist and apperceive fire. Functions and Characteristics 1. industry Gas Monitor and Alarm System,Alarm system monitors the ... the system controller will make a sound& light alarm and close every control valve to avoid any ... China Pacific Insurance Co.,LtdProduct Specification DescriptionCombustible Gas Alarm ControllerCombustible Gas detectorItemHG3000-KZ02/01HG3000-TC01PowerAC220V/50HzDC24VControl ...
Wireless solar siren with strobe, waterproof and tamperproof case.siren hooting time can be set ... sealed lead acid, rechargeable, battery which ensures the Siren and Strobe is powered during the night. The Solar panel is only ... winter days.Features include: 1.Full Tamper Protection(it will alarm if someone want to remove or destroy the solar siren ...
... air-purifier,max current 3A resistanceWarning alarmTwo CO alarm levels presetBuzzer alarmAlarm starts when CO measurement reach ... presetsLCD backlitGreenoptimal air quality Yellow1st CO alarm level Red-2nd CO alarm level Modbus RS485 Interface(option)Communication ... standardWire section area <1.5mm2Quality SystemISO 9001HousingPC/ABS fire-proof, IP30 protectionCertificateCE 1.CO controller real time ...
... gases Semiconductor sensor inside Relay and valve output GD gas alarm, is designed to detect the concentration of combustible, explosive and ... equipment, open windows or shut off gas supply to avoid fire, explosion, suffocation, and other malignant accidents.Working voltage: AC220V/110V ...
... : (diameter) 101×34mm When one alarm, they others all get alarm! The smoke alarm works on the principle that infrared scatters ... initial stage of the fire. It consists of photoelectric system, signal processing identification circuit and alarm circuit. The infrared ... photoelectric signal current. The photoelectric signal generates the alarm signal after being processed by the identification circuit, ...
... center Transparent data transmission and protocol conversion DTU / SMS DTU / Alarm Function 1) Embeded PPP,TCP/IP protocol2) Transparent data transmission ... monitoring2) Remote automatic reading meter system3) Water pollution monitoring4) Forest fire fighting5) Meteorological data collection6) Environmental protection bureau Technical parameter A ...
... , Wireless door magnenic Smoke,gas,flu Burglar Alarm FeaturesAnti-theft,fire,anti-gas leak,emergency alarm,such as diversificationScroll to the code can ... to wireless door magnenic Smoke,gas,flu,on-site emergency alarm
... in the spot, intercom, speaking after answering the alarm call. The alarm has two kinds record: operation voice guide and ... Frequency: 433 MHZ Standard Package list of the GSM Alarm SystemMain panel X1Metal Remote contoller X2Wireless PIR Motion Sensor X1Wireless ... SensorDoor/Window Sensor indoor siren with flashOutdoor siren with strobe panic button wireless signal repeaterOur Other Wired or Wireless ...
... field view, reliable performance RHZKF6.8/30-1 Positive Pressure Fire-fighting Air Respirator This is personal protective equipment which is ... used in fire-fighting. The dexterous equipment is reliable and easy to operate ...
... by I/Ofunction without receiver''s siren or alarm voice ,the last one is testing mode -receiver ... make alarm siren without sending singal to IPcamera in order ... photo .just want to test if the receiver can alarm .that is all . 4.Door sensorWhen roll gates ... opened fire at the police, door status switch to "host " panel. Sending touch alarm signal from a host of alarm ...
this is 9V battery smoke alarm use for home 9V Photo Electric Smoke Alarmdetect smoke will alarm before fire Photo Electric Smoke AlarmSpecifications:.Power source: DC9V, AC110V/AC220V, DC9V/AC110V/AC220VStatic current: <10uAAlarm current: <10mA;Alarm sound: >85dB (3M)Ambient temperature: -10~40°CAmbient humidity: ≤95% (40±2°C)Low battery Alarm: 6V±0.5V OEM are welcome
... controlled intensively. It will give acoustic and visual alarm when the gas concentration reaches or exceeds the preset ... order to prevent suffocation or poisoning accident, explosion and fire. So this system can guarantee the security of production. ... failure inspection for the system and detector, display driver, alarm indication, alarm interlink output, etc;• LED display with high brightness;• Menu ...
Gas leak detector alarm 90dB sound&small volume imported sensor 2+2 LED display ... practical technical & appearence patent Characteristics (GQB-200G8 Gas leak detector alarm) Fixed oxygen and toxic gas detection alam for industrial and ... practical new technique.2. two patents of appearance technique.3. fire control type approval of the ministry of public security.4 ...