Welcome to B2BAGE
Electronic Ballast for HPS/MH lamp ~320W
Electronic Ballast for HPS/MH lamp ~320W

Minimum Order: 0
Quality/Safety Certification: 0.00


High performance Energy saving Excellent operating performance Low harmonic distortion Full-functional protection

> Product Introduction
Our 320W EB with 320W MH lamp has been tested by China and the United States National Laboratory (LBL), their results show its luminous efficacy is 120-130 LMW(lumen per Watt) which exceeds conventional MB 400W MHs luminous efficacy. Therefore it can be used to replace MB 400W MH and achieve high energy-saving.

> Type: AR/EB HPS/MH 320W Power: 320W

Characteristic of InputCharacteristic of Output
Rated Voltage (V)110V240VHarmonic Distortion<10%
Input current (A)1.423.04ACrest Factor<1.50
Frequency (Hz)50/60HZFrequency (Hz)25100KHZ
Power Factor>0.99Loss of Input Watts (%)<10%
  Energy Saving30%

AR/EB 320W for metal halide lamp is named King of Energy-Saving.
Compare luminous efficacy between AR/EB 320W MH and MB 400W MH:

Ballast result+400W standard MH Lamp400W MB
+High luminous
MH lamp
Result
Luminous efficacy120 lm/w70 lm/w95 lm/wLuminous flux:
AR/EB320W + 320W MH lamp exceed 400W MB + 400W MH lamp
Luminous flux38,400 lm28,000 lm38,000 lm


Notethe luminous efficacy of AR/EB 320W MH is 130 lmw60Hztesting by US Light Source Institution.
Testing conditions: Outdoor, factory, building and business lighting with MB and AR/EB
Comparison of Performance and Energy Consumption (Consumption RMB 0.60/kWh)
We test a group of MH lamps (100pcs) with 400W MH + 400W MB (with capacitance) systems. Then we tested the MH lamps with 320W MH + AR/EB 320W,The lamps are on 12 hours per day.
Results are as follows: 

capacitance
 
*According to this table,if we use AR/EB, we can save RMB 35,740.80 per year; and total luminous flux increases by 12%.

Report of Comparison by Testing:

Type400W MB(with capacitance)
+400W MH Lamp
320W AR/EB
+320W MH Lamp
Energy Usage kwh32.6222.82
CurrentA2.2161.583
VoltageV219225
Harmonic distortion29.1%4.6%
Power Factor0.8640.998
Lumens output (lux.)432478
Energy saving 30.02%

Test with MS6610 digital illuminometer, DD862 single-phase ammeter and Yuanfang HB-3A test system at the same condition.