High Voltage Circuit Breaker
Minimum Order: 0
Quality/Safety Certification: 0.00
High voltage SF6 Circuit Breaker
three phase outdoor circuit breaker
spring mechanism
dirtiness resistance
Technical data:
LW8-40.5 outdoor high voltage SF6 circuit breaker | |||
Name | Unit | Value | |
Rated voltage | kV | 40.5 | |
Power frequency withstand voltage/1min | Rated insulating level | kV | 95 |
Thunder impulse withstand voltage(peak value) | 185 | ||
Rated current | A | 2000 | |
Mechanical life | times | 3000 | |
Rated SF6 gas pressure | Mpa | 0.5 | |
Alarm pressure/minimum power pressure(20°C) | Mpa | 0.45/0.40 | |
Rated short-circuit breaking current | KA | 40 | |
Rated short-circuit switching current(peak) | KA | 100 | |
Rated short time withstand current(thermal stability current) | KA | 40 | |
Rated short time withstand current(dynamic stability current) | KA | 100 | |
Rated out of phase breaking curren | KA | 10 | |
Cumulative breaking times of rated short-circuit breaking current | times | 12 | |
Rated short-circuit duration time | s | 4 | |
Switch-off time(on rated voltage) | s | ≤0.15 | |
Switch-on time(on rated voltage) | s | ≤0.06 | |
Rated operating sequence | O-0.3s-CO-180s-CO | ||
Rated switching single capacitor bank current | A | 400 | |
Annual leakage rate of SF6 | %/year | ≤0.5 | |
Water content of SF6(V/V) | PPm | ≤150×10-6 | |
Rated operating voltage matching with CT14 spring operating mechanism | |||
Switch-on/off coil voltage | V | DC 110 220 | |
Energy storage motor voltage | V | AC,DC 110 220 | |
Weight of SF6 gas | kg | 8 | |
Weight of the circuit breaker | kg | 1400 |
Name | Unit | Technical standard | Test condition or means | |
Dynamic contact stroke | mm | 95±2 | Measurement for dynamic contact stroke | |
Clearance between contacts | mm | 60±1.5 | Measurement for clearance between dynamic and static arc contacts | |
Switch-on synchronization between poles | ms | ≤3 | Measurement for clearance between poles of dynamic and static arc contacts | |
Switch-off synchronization between poles | ms | ≤2 | Measurement for clearance between poles of dynamic and static arc contacts | |
Main loop resistance | μ Ω | ≤120 | DC voltage fall measurement, power-on when test | |
Switch-on speed | m/s | 3.2±0.2 | Rated pressure measurement | |
Switch-off speed | m/s | 3.4±0.2 | Rated pressure measurement | |
Switch-on cushioning stroke | mm | 10+0.5-1.0 | Switch-on state | |
Switch-on cushioning orientation distance | mm | 1~2 | Switch-on state | |
48.6kV Partial discharge | PC | 20 | Use part measuring instrument, first measure for 1 min in outlet terminal of breaker on 48.6kV, then drop to 28kV and test again. | |
28kV Partial discharge | PC | 10 |
Outline dimension: