Welcome to B2BAGE
ZN12-12 indoor high voltage vacuum circuit breaker
ZN12-12 indoor high voltage vacuum circuit breaker

Minimum Order: 0
Quality/Safety Certification: 0.00


1.vacuum circuit breaker with IEC standard
2.Rated voltage 12KV
3.Rated current 630/1250/1600/2500/3150
4.OEM service

ZN12-12 indoor high voltage vacuum circuit breaker is a type of 12kv,50HZ three phase alternating switch. The mechanism and vacuum interrupter are designed to be a whole. Specialized 3AF type spring operating structure from Siemens can be operated by manual or carry out direct current energy saving operation. It’s can be designed as 210mm,230mm,250mm,275mm and other kinds of phase space, which matches better with different kinds of switchgear, such as handcart type JYN2-12,JYN6-12,KYN2-12.      

 

Ambient condition

1 Ambient temperature: max +40°C min -15°C(conveyance under -30°C is allowed)

2 Altitude: ≤1000m

3 Relative humidity: daily average relative humidity: ≤95%; monthly average relative humidity≤90%; daily average saturated vapor pressure ≤2.2*10-3 MPa; monthly average value   ≤1.8*10-3 MPa

4 Earthquake intensity: ≤8 degree

5 The installation should be free from fire, explosion, severe vibration, chemical corrosion and serious pollution

 

Order instruction

Complete model and order quantity of the product

Rated current, rated voltage, distance of each poles

Rated short circuit breaking current, operation voltage

Required accessory and quantity

Other requirement please contact with us directly 

 

Main Technical Data    
Rated voltage                                                             kv12
Rated lighting impulse withstand voltagekvInterphase or to ground 75,fructure 80
Rated short-time power frequency withstand voltage(dry)    kvInterphase or to ground 42,fructure 48
Rated short-circuit breaking current                              kA2531.540
Rated current                                                             A

630/1250

/1600

1250/1600

/2000/2500

1600/2000

/3150

Rated thermostability current(valid)kA2531.540
Rated dynamic stability current(peak)   kA 6380100
Rated short-circuit making current(peak)                              kA6380100
Rated operations of short-circuit breaking current interruption   times50(40kA is 30)
Rated working current of overcurrent and tripping coil A5
Rated operating sequence                                             

0-0.3-CO-180s -CO/

0-180s-CO-180s-CO(40KA)

Mechanical life                                           times10000
Rated current of auxiliarate switchAAC10,DC5
Rated voltage of energy saving release vAC,DC220       AC,DC110
Closing time ms≤75
Opening time ms≤60(40)
Power of energy saving motorw275
Energy saving times≤15
Mechanical life                                           times20000

Mechanical characteristics adjustment data

Rated contact stroke mm 11±1

Contact overtravel mm 8±2

Average opening speed m/s 1.0~1.8

Average closing speed m/s 0.6~1.1 0.8~1.3 0.8~1.3

Contact bouncing duration at closing operation ms ≤2

Core distance between phases mm 210,230,250,275

Three-pole simultaneity ms ≤2

Condactive circuit resistance of each phases μΩ <40

 