1.vacuum circuit breaker with IEC standard
2.Reliable and maintenance free
3.Type: VCB
4. OEM service

    The mechanism of this VCB is designed as a whole with vacuum interrupter. Specialized 3AF type spring operating structure from Siemens can be operated by manual or carry out direct current energy saving operation. It’s can be designed as 350mm,400mm,460mm and other kinds of phase space, which matches better with different kinds of switchgear, such as fixed type XGN17-40.5,type JYN1-40.5,KY10-40.5.      

 

Ambient condition

1 Ambient temperature: max +40°C min -15°C(conveyance under -30°C is allowed)

2 Altitude: ≤1000m

3 Relative humidity: daily average relative humidity: ≤95%; monthly average relative humidity≤90%, daily average saturated vapor pressure ≤2.2*10-3 MPa,monthly average value  ≤1.8*10-3 MPa

4 Earthquake intensity: ≤8 degree

5 The installation should be free from fire, explosion, severe vibration, chemical corrosion and serious pollution

 

Order instruction

Complete model and order quantity of the product

Rated current, rated voltage, distance of each poles

Rated short circuit breaking current, operation voltage

Required accessory and quantity

Other requirement please contact with us directly

 

Main Technical Data   
Rated voltage                                                             kv40.5
Rated lighting impulse withstand voltage(peak)kv185
Rated short-time power frequency withstand voltage(1min)     kv95
Rated short-circuit breaking current                              kA2531.5
Rated current                                                             A1250/16001250/1600/2000
Rated peak withstanding currentkA6380
Rated operations of short-circuit breaking current interruption times 20
Rated duration of short-circuit                              s4
Rated operating sequence                                             0-0.3-CO-180s -CO
Supply voltage of open and close installation v AC,DC220 AC,DC110 
Closing time ms50~100
Opening time ms30~60
Rated single capacitor bank breaking current                  A630
Rated back to back capacitor bank breaking current                  A400
Mechanical life                                           times(M1 degree)10000
    
Mechanical characteristics adjustment data   
Rated contact stroke                                      mm22±2
Contact overtravel mm8±2
Average opening speed                                   m/s1.8±0.2
Average closing speed                                    m/s0.65±0.2
Contact bouncing duration at closing operation                ms≤3
Type of operatinf structure Special 3AV sprinf operating structure
Three-pole simultaneity                                     ms≤2
Condactive circuit resistance  of each phases                                 μΩ≤45
    
Note:Rated characteristics can be given on requirment  