Welcome to B2BAGE
MCBs supply DZ47-63/2
MCBs supply DZ47-63/2

Minimum Order: 0
Quality/Safety Certification: 0.00


AC 230/400V Input
Pole No.2P
Rated frequency: 50/60Hz
CE,CCC

Characteristics

Protection against both overload and short circuit
High short-circuit capacity

Its frame and parts adopt plastics of high fire-resistant and shockproof

small apperance.light weight

comply with the standard IEC60898 and GB10963

 

General

1. Application: For protecting cables and equipments against overload and short circuit.

2. General rules for choosing MCB:

a. Technical data of the network at the point considered:

    The earthing systems, short-circuit current at the circuit breaker installation point, which must always be less than the breaking capacity of this device, network normal voltage.

b. There are 3curve characteristics for magnetic operation:

   B curve(3-5 In)protection and control of the circuits against length cables in TN and IT systems.

   C curve(5-10 In)protection and control of the circuits against overloads and short-circuit; protection for resistive and inductive loads with low inrush current.

   D curve(10-14 In)protection and control of the circuits against overloads and short-circuit; protection for circuits which supply loads with high inrush current at the circuit closing(LV/LV transformers, breakdown lamps).

 

Specification

Standard

IEC/EN 60898-1

Electrical

 features

Rated Current In

A

1,2,6,10,16,20,25,32,40,50,63

Poles

P

1,2,3,4

Rated Voltage Ue

V

230/400

Insulation Voltage Ui

V

500

Rated Frequency

Hz

50/60

Rated Breaking Capacity

A

3000,4500

Rated Impulse withstand Voltage(1.2/50)Uimp

V

4000

Dielectric Test Voltage at ind.Freq.for 

1min 

Kv

2

Pollution Degree

 

2

Thermo-magnetic Release Characteristic

 

B,C,D

Mechanical

 features 

Electrical Life

t

4000

Mechanical Life

t

10000

Protection Degree

 

IP20

Reference Temperature for Setting of 

Thermal Element

°C

30

Ambient Temperature (with daily average 

≤35°C)

°C

-5~+40(Special application please refer to temperature 

compensation correction)

Storage Temperature

°C

-25~+70

Installation

Terminal Connection Type

 

Cable/Pin-type busbar

Terminal Size Top/Bottom for Cable

mm2

25

AWG

18-3

Terminal Size Top/Bottom for Busbar

mm2

25

AWG

18-3

Tightening Torque

N*m

2

In-lbs

18

Mounting

 

On DIN rail EN60715(35mm)by means of fast clip device

Connection

 

From top and bottom

 

Temperature Derating

Please refer to table below for temperature compensation correction

Rated Current In(A)

Temperature compensation coefficient under various operational temperature

-10°C

0°C

10°C

20°C

30°C

40°C

50°C

55°C

60°C

1-6

1.20

1.14

1.09

1.05

1.00

0.96

0.80

0.75

0.70

10-32

1.18

1.12

1.08

1.04

1.00

0.96

0.92

0.88

0.84

40-60

1.16

1.12

1.07

1.03

1.00

0.97

0.87

0.83

0.80

 

 

Ads by Google