Meanwell 100W Single Output Waterproof LED Power Supply
Minimum Order: 0
Quality/Safety Certification: 0.00
IP67 led power supply, waterproof LED Power Supply, Meanwell power supply gained the CE, UL, CUL certificate. 3 years warranty
Features of LED Power Supply:Universal AC input / Full range Built-in active PFC function High efficiency up to 90% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection IP67 design for indoor or outdoor installations UL1310 Class 2 power unit Pass LPS 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting 3 years warranty (Note.6) Specification Waterproof LED Power Supply, Meanwell Power Supply:
Model | CLG-100-12 | CLG-100-15 | CLG-100-20 | CLG-100-24 | CLG-100-27 | CLG-100-36 | CLG-100-48 | |
Output | DC VOLTAGE | 12V | 15V | 20V | 24V | 27V | 36V | 48V |
CONSTANT CURRENT REGION Note.7 | 9 ~ 12V | 11.25 ~ 15V | 15 ~ 20V | 18 ~ 24V | 20.25 ~ 27V | 27 ~ 36V | 36 ~ 48V | |
RATED CURRENT Note.5 | 5A | 5A | 4.8A | 4A | 3.55A | 2.65A | 2A | |
RATED POWER Note.5 | 60W | 75W | 96W | 96W | 95.85W | 95.4W | 96W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | Fixed. Can be modified between 0% ~ -15% rated output voltage | |||||||
VCURRENT ADJ. RANGE | Fixed. Can be modified between 3% ~ -25% rated output current | |||||||
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±3.0% | ±3.0% | ±3.0% | ±3.0% | ±2.0% | ±2.0% | |
LINE REGULATION | ±1.0% | |||||||
LOAD REGULATION | ±2.0% | |||||||
SETUP TIME | 1200ms, 80ms / 230VAC; 1200ms, 80ms / 115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 60ms / 230VAC; 30ms / 115VAC at full load | |||||||
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 295VAC; 127 ~ 417VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR (Typ.) | PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) | |||||||
EFFICIENCY (Typ.) | 84.5% | 86.5% | 90% | 90% | 90% | 90% | 89% | |
AC CURRENT (Typ.) | 12V: 0.8A/115VAC; 0.4A/230VAC; 0.3A/277VAC; 15V:0.9A/115VAC; 0.45A/230VAC; 0.35A/277VAC 20V ~ 48V: 1.1A/115VAC; 0.55A/230VAC; 0.45A/277VAC | |||||||
INRUSH CURRENT(max.) | COLD START 40A/230VAC | |||||||
LEAKAGE CURRENT | < 0.75mA / 240VAC | |||||||
PROTECTION | OVERLOAD | 95 ~ 102% | ||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 13 ~ 16V | 16.5 ~ 20V | 22 ~ 27V | 27 ~ 34V | 30 ~ 36V | 39 ~ 48V | 52 ~ 64V | |
Protection type : Shut down and latch off o/p voltage, re-power on to recover | ||||||||
OVER TEMPERATURE | 90°C±10°C(RTH2) | |||||||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70°C (Refer to "Derating Curve") | ||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85°C , 10 ~ 95% RH | |||||||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C ) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||
SAFETY & EMC | SAFETY STANDARDS Note.8 | UL879, UL8750, UL1310 Class 2, TUV EN60950-1, EN61347-1, EN61347-2-13 independent CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved | ||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25°C / 70% RH | |||||||
EMC EMISSION | Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( ≥75% load) ; EN61000-3-3 | |||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A | |||||||
OTHERS | MTBF | 301K hrs min. MIL-HDBK-217F (25°C) | ||||||
DIMENSION | 222.2*68*38.8mm (L*W*H) | |||||||
PACKING | 1.0Kg; 12pcs/13Kg/0.58CUFT | |||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. | |||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | ||||||||
4. Derating may be needed under low input voltages. Please check the static characteristics for more details. | ||||||||
5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. | ||||||||
6. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 . | ||||||||
7. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. | ||||||||
8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18. | ||||||||
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. |