Meanwell 100W Single Output Waterproof LED Power Supply
Meanwell 100W Single Output Waterproof LED Power Supply

Minimum Order: 0
Quality/Safety Certification: 0.00


IP67 led power supply, waterproof LED Power Supply, Meanwell power supply gained the CE, UL, CUL certificate. 3 years warranty

Features of LED Power Supply:Universal AC input / Full range Built-in active PFC function High efficiency up to 90% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection IP67 design for indoor or outdoor installations UL1310 Class 2 power unit Pass LPS 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting 3 years warranty (Note.6) Specification Waterproof LED Power Supply, Meanwell Power Supply:

ModelCLG-100-12CLG-100-15CLG-100-20CLG-100-24CLG-100-27CLG-100-36CLG-100-48
OutputDC VOLTAGE12V15V20V24V27V36V48V
CONSTANT CURRENT REGION Note.79 ~ 12V11.25 ~ 15V15 ~ 20V18 ~ 24V20.25 ~ 27V27 ~ 36V36 ~ 48V
RATED CURRENT Note.55A5A4.8A4A3.55A2.65A2A
RATED POWER Note.560W75W96W96W95.85W95.4W96W
RIPPLE & NOISE (max.) Note.2150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p200mVp-p
VOLTAGE ADJ. RANGEFixed. Can be modified between 0% ~ -15% rated output voltage
VCURRENT ADJ. RANGEFixed. Can be modified between 3% ~ -25% rated output current
VOLTAGE TOLERANCE Note.3±3.0%±3.0%±3.0%±3.0%±3.0%±2.0%±2.0%
LINE REGULATION±1.0%
LOAD REGULATION±2.0%
SETUP TIME1200ms, 80ms / 230VAC; 1200ms, 80ms / 115VAC at full load
HOLD UP TIME (Typ.)60ms / 230VAC; 30ms / 115VAC at full load
INPUTVOLTAGE RANGE Note.490 ~ 295VAC; 127 ~ 417VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)84.5%86.5%90%90%90%90%89%
AC CURRENT (Typ.)12V: 0.8A/115VAC; 0.4A/230VAC; 0.3A/277VAC; 15V:0.9A/115VAC; 0.45A/230VAC; 0.35A/277VAC
20V ~ 48V: 1.1A/115VAC; 0.55A/230VAC; 0.45A/277VAC
INRUSH CURRENT(max.)COLD START 40A/230VAC
LEAKAGE CURRENT< 0.75mA / 240VAC
PROTECTIONOVERLOAD95 ~ 102%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUITHiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE13 ~ 16V16.5 ~ 20V22 ~ 27V27 ~ 34V30 ~ 36V39 ~ 48V52 ~ 64V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE90°C±10°C(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENTWORKING TEMP.-30 ~ +70°C (Refer to "Derating Curve")
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85°C , 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/°C (0 ~ 50°C )
VIBRATION10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMCSAFETY STANDARDS Note.8UL879, UL8750, UL1310 Class 2, TUV EN60950-1, EN61347-1, EN61347-2-13 independent
CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved
WITHSTAND VOLTAGEI/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P:100M Ohms / 500VDC / 25°C / 70% RH
EMC EMISSIONCompliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( ≥75% load) ; EN61000-3-3
EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
OTHERSMTBF301K hrs min. MIL-HDBK-217F (25°C)
DIMENSION222.2*68*38.8mm (L*W*H)
PACKING1.0Kg; 12pcs/13Kg/0.58CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
6. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 .
7. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.