Meanwell 50W Single Output LED Driver
Minimum Order: 0
Quality/Safety Certification: 0.00
Meanwell LED Driver, LED Power Supply, LED Transformer gained CE,CB, UL certificates. 2 years warranty
Features of LED Driver, LED Transformer:Universal AC input/Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test 2 years warranty
Specification of LED Power Supply:
Model | NES-50-5 | NES-50-12 | NES-50-15 | NES-50-24 | NES-50-48 | |
Output | DC VOLTAGE | 5V | 12V | 15V | 24V | 48V |
RATED CURRENT | 10A | 4.2A | 3.4A | 2.2A | 1.1A | |
CURRENT RANG | 0 ~ 10A | 0 ~ 4.2A | 0 ~ 3.4A | 0 ~ 2.2A | 0 ~ 1.1A | |
RATED POWER | 50W | 50.4W | 51W | 52.8W | 52.8W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | |
VOLTAGE ADJ. RANGE | 4.75 ~ 5.5V | 10.8 ~ 13.2V | 13.5 ~ 16.5V | 21.6 ~ 26.4V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load | |||||
HOLD UP TIME (Typ.) | 50ms/230VAC 10ms/115VAC at full load | |||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC , 120 ~ 370VDC | ||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
EFFICIENCY(Typ.) | 79% | 82% | 83% | 86% | 87% | |
AC CURRENT (Typ.) | 1.1A/115VAC 0.65A/230VAC | |||||
INRUSH CURRENT (Typ.) | COLD START 45A | |||||
LEAKAGE CURRENT | < 2mA / 240VAC | |||||
PROTECTION | OVERLOAD | 110 ~ 150% rated output power | ||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25 | 27.6 ~ 32.4V | 55.2 ~ 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||
ENVIRONMENT | WORKING TEMP. | -20 ~ +60°C (Refer to "Derating Curve") | ||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||
STORAGE TEMP., HUMIDITY | -40 ~ +85°C , 10 ~ 95% RH | |||||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 45°C ) | |||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||
SAFETY & EMC (Note 6) | SAFETY STANDARDS | UL60950-1, CB(IEC60950-1),CCC GB4943 approved | ||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH | |||||
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | |||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A | |||||
OTHERS | MTBF | 374.2K hrs min. MIL-HDBK-217F (25°C) | ||||
DIMENSION | 129*98*38mm (L*W*H) | |||||
PACKING | 0.41Kg; 45pcs/19.5Kg/1.24CUFT | |||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. | |||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor | ||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | ||||||
4. Line regulation is measured from low line to high line at rated load. | ||||||
5. Load regulation is measured from 0% to 100% rated load. | ||||||
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) |