Tongdy [China]
Model No: F2000IAQ-CO2-31XXU
Place of Origin: Beijing,China
Brand Name: Tongdy
Packaging: full and firm package
Minimum Order: 100pcs
Quality/Safety Certification: CE
Features
u Real-time monitoring carbon dioxide (CO2) measurements during 0ppm to 20,000ppm range
u Optional real-timemonitoring temperature from -20℃ to 60℃ and relative humidity from 0 to 100%RH
u Non-dispersive infrared (NDIR) CO2 sensor with self calibration, 15 years lifetime
u The 3-LED indicator lights indicate three CO2 measured ranges
u LED lights brightness adjustable
u Provide 1X0~10VDC output for alternative linear
CO2 measurement and PID control output
u Provide 1X On/Off dry contact output to control alternative a ventilator and a CO2 generator
u An internal data logger is used to record CO2measurements as well as optional temperature and RH% measurements.
u With super large capability memorizer, it can save data of up to 115 days
u Provide the software to preset the sampling time, read and record CO2/temperature&RH levels on PC
u Post the data from the internal memorizer by any USB disk, and copy the data to a PC
Specifications
Gas detected
|
Carbon Dioxide (CO2)
|
Sensing element
|
Non-Depressive Infrared Detector (NDIR)
|
CO2 NDIR life
|
15 years
|
Accuracy@25℃(77℉)
|
±40ppm + 3% of reading
|
Stability
|
<2% of FS over life of sensor (15 yr typical)
|
Calibration interval
|
ABC Logic Self Calibration Algorithm
|
CO2 measuring range
|
0~2000ppm -default value
Up to 0~20,000ppm, programmable selection
|
CO2 setting & Display resolution
|
1ppm
|
Pressure Dependence
|
Can be preset the altitude by the end users to eliminate the pressure influence via a inside software
|
Temperature& RH sensor (optional)
|
Combined digital temperature and relative humidity sensor
|
Temperature measurement range
|
-20℃~60℃(-4℉~140℉)
|
Humidity measurement range
|
0~100%RH
|
Temperature& RH accuracy
|
±0.5℃/ ±3%RH
|
Option: 1X dry contact output
|
Rated currency for contact point: 3A220VAC/30VDC, resistance load
|
Optional:1xanalog output
|
0~10VDC or 4~20mA analog output for CO2 measurement
|
Operation condition
|
-20℃~70℃, 0~95%RH (non-condensing)
|
Power supply
|
24VAC/VDC ±10% wiring connection
Or with a power adaptor of 24V/230V or 24V/110V
|
Consumption
|
3.5W/ Max, 2.5W/ Average
|
Weight
|
380g
|
Dimensions
|
130mm×90mm×40mm
|
Connections Interface
|
Locate in interface of connection
|
Installment standard
|
65mm×65mm or 2”×4” wire box
|
Wiring standard
|
Wire section area<1.5mm2
|
Approval Standard
|
CE-Approval
|
Presetting and operation
|
Buttons and internal DIP switches
|
Sampling alternation
|
Preset the sampling alternation during 60s to 1h. The general maximum
day of the data record is 60 days
|
Software Features
|
Outputs date is in .txt format
USBDataGather software is for stand-alone application. It’s used to set parameters for different applications, to display the graph of capture data, to calculate the average value of a period, as well as the max. and min. value
|