1.Outdoor disconnect switch, disconnecting switch
2.Silicone insulator.
3.Short delivery time
4.11kV,12kV, 110kV BIL.

    The disconnect switch is used to isolate or sectionalize circuit on electrical distribution system through 12kV.

It is a single-phase isolation switch,it provides a visible fracture of maintenance personnel,can be used as asub-breakpoint.The structure of double-cdumn isolation switch,in sulator bolt locked in a hot-dipzinc corrosion protection on the base,pull ring can be operated disconnect switch. 

Specification

1). Rated for continuous current: 630 or 900A;

2). Rated voltage: 12kV;

3). Peak withstand current:65kA;

4). Lightning impulse voltage(BIL):110kV

Product detailed features

1). Base plate and back strap: made of hot galvanized steel for against corrosion, and ensure solid operation.

2). Insulators: made of silicone.

3). Contacts: silver to silver contacts guarantees long life.

4). Copper blade: silver-plated copper.

5). Loadbreak hook: made of galvanized steel, anti-corrosion.

6). Standard dual-hole plated pad or optional two-piece parallel groove.

7). Pull-ring: serves as lever to activate the latch for easy operating.

8). Blade limit design: control the blade range of motion to 90°and 160° position.

Standard:

IEC 6227-102    3.6kV-40.5 kV high voltage AC disconnect switch and earthing switch

Technical parameter

Product specification

DCD-12/630

DCD-12/900

Rated voltage

12kV

12kV

Rated current

630A

900A

Rated frequency

50Hz

50Hz

Rated short time withstand current

25kA/3S

25kA/3S

Rated peak withstand current

65kA

65kA

 

Rated power frequency withstand voltage

(dry, 1 minute)

to earth

54kV

54kV

across isolating distance

61.5kV

61.5kV

 

Rated power frequency withstand voltage

(wet, 1 minute)

to earth

38.5kV

38.5kV

across isolating distance

46.5kV

46.5kV

 

Lightning impulse withstand voltage(BIL)

to earth

110kV

110kV

across isolating distance

110kV

110kV

Creepage distance

≥ 496mm

≥ 496mm

Creepage proportion

≥41mm/kV

≥41mm/kV

Loop resistance

≤62μΩ

≤62μΩ

Mechanical life

2500CO

2500CO

Weight

≈7kg

≈8kg

 

Dimensions diagram

 

 

Installation diagram

The disconnect switch can be installed according to the following diagram:

1).vertical or underhung

2)single or double crossarm

 

Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.