Welcome to B2BAGE
xlpe steel wire armoured cable
xlpe steel wire armoured cable

Minimum Order: 0
Quality/Safety Certification: 0.00


XLPE steel armoured
1.used for laying in buildings,tunnels or trenches
2. Standard: IEC60502; GB/T12706
3.20 years experience

XLPE steel wire armoured cable

1). Standard: IEC60502; GB/T12706

2). Specification:

     * Aluminium conductor for single core or multi-core;

     * XLPE or PVC insulated;

     * Armoured or unarmoured;

     * PVC sheathed power cable.

 

3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:

        U0/U(Um) =3.6/6(7.2)-6/10(12)-8.7/15(17.5)-12/20(24)-18/30(36)-21/35(40.5)KV

   In the voltage designation of cables U0/U(Um):

        * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;

        * U is the rated power frequency voltage between conductors for which the cable is designed;

        * Um is the maximum value of the "highest system voltage" for which the equipment maybe used

 

4) Voltage:0.6/1kv,6/6kv,6/10kv,8.7/15kv,12/20kv,18/30kv,19/33kv,26/35kv

 

5). Application:used in ducts, trays and direct burial in ground. the cable is subjuct to immerse in water all the time.

 

6).This series includes:Single copper(Alumunium) core XLPE insulated PVC sheated

    * Single copper(Alumunium) core XLPE insulated  steel tape armoured PVC sheathed

    * Single copper(Alumunium) core XLPE insulated steel wire armoured PVC sheateed

    * Multi-core copper(Alumunium) core XLPE insulated PVC PVC sheath

    * Multi-core copper(Alumunium) core XLPE insulated PVC inner sheath steel tape armoured PVC  sheath

    * Multi-core copper(Alumunium) core XLPE insulated PVC  inner sheath steel tape armoured PVC sheath

 

7).Product feature

    a.Max Long-time operating temperature of XLPE insulated cable is 90(70)°C.

    b.Installing temperature of cable should not be less than 0°C.

    c.Max short-circuit temperature is not exceed 250(160)°C, not more than 5 sec.

 

8). Marking: According to the customers' requirements

 

type

No. of cores

0.6/1 KV

6/6KV

6/10KV

8.7/15KV

12/20KV

18/30KV

19/33KV

26/35KV

mm2

Copper/XLPE/PVC

1

1.5-800

25-800

35-1200

50-1200

Aluminum/XLPE/PVC

2.5-1000

25-1000

35-1200

50-1200

Copper/XLPE/SWA/(STA,SWA)PVC

10-1000

25-1000

35-1200

50-1200

Copper/XLPE/PVC

3

1.5-400

25-400

35-400

50-400

Aluminum/XLPE/PVC

2.5-400

25-400

35-400

50-400

Copper/XLPE/SWA/PVC

4-400

25-400

35-400

50-400

  

 

 

Ads by Google