TYN-I P Controller of Solar Lamps
TYN-I P Controller of Solar Lamps

Minimum Order: 0
Quality/Safety Certification: 0.00


Accumulator cell management
Multi controlfunctions
Automatically initiate in the evening
Data collection and Digital display

 

Introduction of TYN-P Controller of Solar Lamps

 

TYN-P controller of solar lamps is the intellectualized controller, uses the advanced programmable microchip and the specialized software. It is an multi-purpose intellectual controller which based on the scientific software designs and the reliable hardware technologies, and provides novel appearance, complete functions, high performance and reliable quality. TYN-P controller can be applicable to all kinds of solar street lamps and solar power supply system.

 

1)The functions and features of TYN-I P controller of solar lamps:

1. Accumulator cell management: ensure the best state (charge and discharge) of accumulator cell. By avoiding the state of over-charge or over-discharge, assure batterys expected life-span

2. Multi controlfunctions: Light control(sunlight intensity), time control(for lamp or output of electrical appliance), temperature control(automatically adjust controlparameters along with the change in ambient temperature),etc..

3. Automatically initiate in the evening, lights on before midnight (time adjustable) and lights off after midnight and during daytime. Time of turning on the lights can be changed by setting on the panel.

4. Data collection and Digital display: Through many circuit A/D mode-data change circuit in the microchip , automatically collect data of work parameters of solar power system(voltage of accumulator cell, PV-voltage of solar battery, time of turning on lights before midnight, etc.) and manual cycle display through Digital tube

5. Automatic temperature complement control: automatically change the value of control parameters of battery management program, so as to prevent the low charge in winter or over charge in summer.
6. Automatic protections: Reversed connect protection, Accumulator battery open circuit protection, prevent anti-charge protection in midnight, output short circuit protection, and etc..

2)Technical Specifications of TYN-I P controller of solar lamps

number

Work name

technology

1

rated voltage

12V or 24V

2

rated current

10A

3

over-charge point

14.4V±0.1V or 28.8V±0.2V

4

over-charge recover point

13.2V±0.1V26.4V±0.2V

5

over-discharge point

10.8V±0.1V21.6V±0.2V

6

over-discharge recover point

12.3V±0.1V24.6V±0.2V

7

ambient temperature

-20-60

8

altitude for use

less than 5000 meters

 

3)External connections of TYN-P controller of solar lamps

 

1.      Connect controller, please connect accumulator cell first, then solar battery, and street lamps at last.

2.      Disconnect the controller ,please disconnect solar battery first, then lamps, and accumulator cell at last.

Notes for Connection:  

1. Do not reverse connect the anode and cathode of solar batteries, accumulator cells and lamps.
2. Do not connect accumulator cells to the terminal of solar batteries

3. Do not connect regulator n. or any charger to the terminal of solar battery.

4. Please choose multi-strand copper wire with over Φ2.0mm for connection, and tighten the screws at all time.

4)Instructions for TYN-P controller of solar lamps

1. Press down the system establishment button for 5 seconds, after digit LED twinkles, loosen the button, presses once to change the number every time until the number demonstrated on digit LED equals the number of mode chose from table by user. The establishment finishes when digit LED stops twinkling. The number can be observed every time LED lightens up while pressing the button.

2. Mode of The Pure light control: when there is no sunlight, luminous intensity fall to the initiating spot. After the controller confirming signal of startup in 10 minutes delay, the load start to work. When there is sunlight, luminous intensity rise to initiating spot. After the controller confirming the signal of output turnoff in 10 minutes delay, the load stop working.

3.Mode of Light control+ Time delay: startup process as previous. The load will shut down after work to the reserved time. Time setting table as follows.

4. General Mode of control: this mode disables light control, time control, output time delay and related functions, reserves all the rest functions. Controller under this mode is used as general controller

5. Debug mode: applies to system debugging. It is similar to pure light controlmode, which only disabled 10 minutes delay and retains all the other functions. Load connects when there is light signal and disconnect when not, which is convenient for examining the system establishment

6. Explanation of output mode: When the LED digital tubes display the reserved number of mode, if demonstrate a discrete number (0-5), then there is pure direct current output. Inductive and condensive load are prohibited.