Drop Wire Module
Subscriber Terminal Block
Insulation Displacement Connecter
Subscriber Connector Unit
Quick Connect Module
The STB module provide a connection point between an exchange-side cable pair and a distribution pair. It incorporates a 5-point plug in module to provide continuity and a range of other options. Removal of the plug-in module does not disturb wire connections but makes contacts to them available for testing of both sides of the network.
It is especially recommended for:
1. Outdoor connections where the enviromental conditions are extremely agressive.
2. Terminations where user development characteristics require future flexibility in terms of the type of protection or filtering capabilities.
Current conducting capacity
20 A, 10 A per conductor for 10 minutes at least, without causing deformation to the module
Insulation resistance
Dry atmosphere: >1010 Damp atmosphere(ASTM D618, procedure F): >1010 Salt fog:(ASTM B117) >109
Immersion in water: (15 days in 3% NaCl solution) TELCORDIA TR-NWT-000975 (Formerly Bellcore)>109
Contact resistanceRmaterial + Rbridge contacts + Rwire contacts <10 m
Increase in contact resistanceAfter climatic tests: <2.5 m After 50 reinsertions: <2.5 m
Dielectric strength >3,000 Vdc for 1 minute
Mechanical characteristics
Protector ground contactTinned hard brass Continuity contactTinned hard brass
Plug-in module bodyFlame retardant (UL94) fiber-glass reinforced polycarbonate
Plug-in module sealantGel O ring EPDM
Internal ConfigurationContinuityASSTB 260 V GDT230 V GDTAS-STB-P
Drop wire connector module
Subscriber terminal block
STB module ANSHI
Disconnection Module
STB module with protection
Drop Wire Module
Subscriber Terminal Block
Insulation Displacement Connection
Disconnection Module
Quick Connect Module
DROP WIRE TERMINATION
ANSHI Subscriber terminal block Drop wire module
ANSHI 1 Pair Subscriber Terminal Block Module With Protection
ANSHI GAS Subscriber Terminal Block Module