Subscriber Terminal Block Module
Drop Wire Module
Disconnection Module
Distribution STB Module Box
Wire Connection Module

The Subscriber Terminal Block module provide a connection point between an exchange-side cable pair and a distribution pair. It incorporates a 5-point plug in module to provide continuity and a range of other options. Removal of the plug-in module does not disturb wire connections but makes contacts to them available for testing of both sides of the network.


1. Outdoor connections where the enviromental conditions are extremely agressive.
2. Terminations where user development characteristics require future flexibility in terms of the type of protection or filtering capabilities.
Current conducting capacity
20 A, 10 A per conductor for 10 minutes at least, without causing deformation to the module
Insulation resistance
Dry atmosphere: >1010 Damp atmosphere(ASTM D618, procedure F): >1010 Salt fog:(ASTM B117) >109
Immersion in water: (15 days in 3% NaCl solution) TELCORDIA TR-NWT-000975 (Formerly Bellcore)>109
Contact resistanceRmaterial + Rbridge contacts + Rwire contacts <10 m
Increase in contact resistanceAfter climatic tests: <2.5 m After 50 reinsertions: <2.5 m
Dielectric strength >3,000 Vdc for 1 minute
Mechanical characteristics
Protector ground contactTinned hard brass Continuity contactTinned hard brass
Plug-in module bodyFlame retardant (UL94) fiber-glass reinforced polycarbonate
Plug-in module sealantGel O ring EPDM
Internal ConfigurationContinuityASSTB 260 V GDT230 V GDTAS-STB-P

Size: (mm) (H x W x D):  46 x 50 x 20 (without Protection) Environment condition: 5-40 degree Celsius ,Relative humidity <85% (+30 degree Celsius),Atmospheric pressure: 70-106KPa Pulling-out force: tin bronze and silver plating (20-40uinch), pulling-out force not less than 25N The performance of anti-burn: PBT or anti-burn PC ,Combustibility achieved GB/T 5169.7-1985 standard Type: 1) without Protection: DIN rail drop wire connector with continuity plug. The plug is grey in colour and has only the function of electrically connecting the incoming pair with the outgoing one. 2) with Protection: DIN rail drop wire connector with 3-point protection: It differs from previous one by having a RED plug, which, beside providing continuity, also integrates a 3-pole gas arrestor (GDT), rated 230V, 5A/5kA Life: durability 200 cycles (0.4-0.6 diameter), durability 50 cycles (0.6-1.2 diameter) Testing-generalElectricalMechanicalEnvironmental and so onaccording to industry standard Material and Production Stamp and Product Branding: according to Client standardInsulation displacement (IDC) Type Connections


1 pair drop wire connection module with protection (STB)
Drop Wire Connection Module With Protection (STB)

ANSHI 1 pair Subscriber Terminal Block Module (STB)

Drop Wire splice protection box

ANSHI 1 Pair Subscriber Terminal Block Module With Protection


         

Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.