Welcome to B2BAGE
DC Contactor for Locomotive
DC Contactor for Locomotive

Minimum Order: 0
Quality/Safety Certification: 0.00


Electromagnetic drive; module structure; are generalized, standardized, and have various models.

OV1000 series DC contactors can be applied for railway diesel locomotives, subway rolling stocks, EMU (electronic multiple units), DMU (diesel multiple units) and other industrial electric automation control equipment. Such DC contactors are used to control circuit in locomotives and rolling stocks.

 

The production standards comply with GB/T 21413.1-2008/IEC 60077-1:1999; GB/T 21413.2-2008/IEC 60077-2:1999.

 

The whole contactor structure is consisted of magnetic circuit and arc distinguishing cover. According to load current and installation size, tailored contactors of such series can be produced via module design to meet customer's demands.

 

Magnetic coil ends of such DC contactors are equipped with voltage suppressor which can inhibit the self-induced electromotive force of the coil. Auxiliary contact has fast-moving, self-cleaning, sealing and permanent magnetic air distinguishing characteristics

 

Technical Parameters

Main Contact

 

Rated Voltage (Ue)

DC 110V (OV1001 series)

 

DC 750V (OV1008 series)

 

DC 1000V (OV1010 series)

 

DC 1500V (OV1015 series)

Rated Current (Ie)

DC 630A (OV1001/06 series)

 

DC 800A (OV1010/08 series)

 

DC 1000A (OV1010/10 series)

Auxiliary Contact

 

Rated Voltage (Ue)

DC 110V

Conventional Thermal Current (Ith)

DC 10A

Rated Current (Ie) (DC-13)

DC 1A

Protection Class (Pollution Level 3)

 

Whole Contactor & Auxiliary Contact Wiring

IP00

Auxiliary Contact

IP40 (OV866 a/L)

 

IP60 (OV867 W2A2b)

Us = 100V long-time working system

About 72W (OV10xx/10 series)

 

About 40W (OV10xx/04,06,08 series)

Us = 80V short-time working system

About 60W (OV10xx/04,06,08 series)

Weight

About 9 Kg (OV1001/06 series)

 

About 10 Kg (OV1010/08 series)

 

About 20 Kg (OV1010/10 series)

Mechanic Life

Over 106 times

Electric Life

Over 105 times

 

Models Selection

 

1-  OV1000 series DC contactors are widely used in diesel locomotives, including models OV1001/06-PB-44-80V, OV1010/08-EH-33-110V, OV1010/08-PA-44-110V, etc.

2-  Coil control voltage of OV1000 series DC contactors can be DC 12V, 24V, 48V, 74V, 80V and 110V, and coil working voltage is between 80% and 110%.

3-  External wiring mode is below:

     Main Contact:    

     Connected copper wiring hole: Φ9 (OV1001/06-PC-33-110V contactor)

                                                      Φ11 (Standard OV1000 series DC contactors)

                                                      Φ13 (OV1001/06-PC-33-110V & OV1010/10-PA-44-110V)

                                                      M10 Screw (OV1001/06-PB series DC contactors)

     Coil Wiring:      M4 Screw

     Auxiliary Contact: M3 Screw   A6.3×0.8 insert (DIN41636)

4-  OV1000 series DC contactors can be equipped with at most 4 sets of auxiliary contact (4NO + 4NC).

5-  When 96V storage battery is used for contactor coil power supply, coil control voltage of the contactor should be 80V which can ensure enough contact pressure.

6-  When voltage suppressor is parallel connected to two ends of coil, wiring should be as per polarity signs.

 

Please contac us if you are interested in such contactors. Wiring Diagram and Structural Size information is available.